EXCHANGERS 114741
Unused 284 sq. ft. Horizontal heat exchanger. Mfg by Fabsco Shell and Tube in 2023.. 2.32 Design duty (MMBTU/Hr). Shell Design Rating: 95/FV psi @ 300 deg. F. Tube Design Rating: 120 psi @ 150 deg. F. Shell mawp ...
Cleveland, TXEXCHANGERS 114749
Unused 112 sq. ft. heat exchanger. Mfg. by Fabsco Shell and Tube in 2023. 0.203 Design duty (MMBTU/Hr). Shell Design Rating: 425/FV psi @ 300 deg. F. Tube Design Rating: 330 psi @ 150 deg. F. Shell mawp 430/FV p...
Cleveland, TXEXCHANGERS 114724
Unused 87 sq. ft. heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 0.19 Design duty (MMBTU/Hr). Shell Design Rating: 160/FV psig @ 300 deg. F. Tube Design Rating: 125 psig @ 150 deg. F. Shell mawp 626.7...
Cleveland, TXEXCHANGERS 114723
Unused 47 sq. ft. heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 0.099 Design duty (MMBTU/Hr). Shell Design Rating: 220/FV psig @ 300 deg. F. Tube Design Rating: 170 psig @ 150 deg. F. Shell mawp 454....
Cleveland, TXEXCHANGERS 114719
Unused 367 sq. ft. horizontal heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 2.05 Design duty (MMBTU/Hr). Shell Design Rating : 170 psig @ 150 deg. F. Tube Design Rating: 215/FV psig @ 330 deg. F. Shel...
Cleveland, TXEXCHANGERS 114491
Used 22 sq. ft. 304 Stainless Steel Heat Exchanger. Mfg. by Perry Products in 1991. Model #6-22FTSSX. Shell: 304 Stainless Steel, 85 psi @ 300 deg. F. Tubes: 304 Stainless Steel 35 psi @ 300 deg. F. 6" diameter x...
Cleveland, TXEXCHANGERS 114490
Used 15 sq. ft. 304 Stainless Steel Heat Exchanger. Mfg. by Perry Products in 1991. Model #4-15FTSSX. Shell: 304 Stainless Steel, 85 psi @ 300 deg. F. Tubes: 304 Stainless Steel 35FV @ 300 deg. F. 4" diameter x 5...
Cleveland, TXEXCHANGERS 113206
Used 140 Estimated Sq. Ft. Vertical 304L Stainless Steel Plate Heat Exchanger. Mfg. by APV in 2015. With Carbon Steel Frame and 304L Stainless Steel Plates. Model #SR2-M12. Rated mawp FV/150 psi @ 329 deg. F. md...
Cleveland, TXEXCHANGERS 114252
Previously Utilized in an API Facility. Used Condenser for ST-1601; 90 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Patterson Kelley. 316 Stainless Steel tubes MOC.
Cleveland, TXEXCHANGERS 108629
LIQUEFACTION COOLER; 6.7 SQ. FT. PLATE HEAT EXCHANGER; MFG. BY ALFA LAVAL IN 2011; MODEL #TL3-PFG; NBRP GASKETS; PLATE THICKNESS .50MM;
Cleveland, TXEXCHANGERS 114736
Unused 1,826 sq. ft. horizontal heat exchanger. 14.73 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. . Shell Design Rating: 95/FV psig @ 300 deg. F. Tube Design Rating: 120 psig @ 150 d...
Cleveland, TXEXCHANGERS 114777
Unused 832 sq. ft. vertical heat exchanger. Mfg. by Fabsco Shell and Tube in 2024. 9.17 x 1.1 Design duty (MMBTU/Hr). Shell Design Rating: 150/FV psi @ 350 deg. F. Tube Design Rating: 120 psi @ 150 deg. F. Shell...
Cleveland, TXEXCHANGERS 114747
Unused 669 sq. ft. horizontal heat exchanger. 6.82 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. Shell Design Rating: 304/FV psig @ 340 deg. F. Tube Desing Rating: 232/FV psig @ 430 deg...
Cleveland, TXEXCHANGERS 114244
Used 26 sq. ft. Shell & Tube small horizontal Exchanger. Mfg. by Futura Titanium Corp. Titanium tubes MOC. Model #WF6-1-48. (50) tubes, 4' tube length.
Cleveland, TXEXCHANGERS 114260
Previously Utilized in an API Facility. Used 320 sq. ft. horizontal Shell & Tube horizontal Exchanger. Mfg. by Perry Products in 1989. 316 Stainless Steel tubes MOC. Shell 90 psi.
Cleveland, TX