EXCHANGERS 113104
"As Is, Where Is" Unused Karbate Poly Bloc Heat Exchanger. Teflon Impregnated. Mfg. by Mersen in 2018. Model #PB24-20-TH-1-2. (1) Pass Axial, (2) Pass Radial, (20) Blocks. Graphite Block data. Total process side ...
Cleveland, TXEXCHANGERS 113511
Used 2633 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 32" diameter x 20'0" F/F. Shell: Carbon Steel, 75FV psi @ 300 deg. F. Tubes: 316L Stainless Steel, (503) 1" O.D. x 16 BWG, 75FV ...
Cleveland, TXEXCHANGERS 113515
Used 930 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 18" diameter x 20'0" F/F. Shell: Carbon Steel, 75FV psi @ 250 deg. F. Tubes: 316L Stainless Steel, (237) .75" O.D. x 16 BWG, 75FV...
Cleveland, TXEXCHANGERS 113512
Used 706 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 38" diameter x 6'0" F/F. Shell: Carbon Steel, 75FV psi @ 300 deg. F. Tubes: 316L Stainless Steel, (300) 1.5" O.D. x 16 BWG, 75FV ...
Cleveland, TXEXCHANGERS 102852
- Manufacturer: OHMSTEDE
FRESH WATER COOLER; SHELL MFG BY OHMSTEDE IN 1995; BUNDLE IN 2007; HEAD MFG. BY GULF COAST HEAT EXCHANGER IN 2001;
Cleveland, TXEXCHANGERS 113516
Used 733 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 24" diameter x 10'0" F/F. Shell: Carbon Steel, 75FV psi @ 300 deg. F. Tubes: 316L Stainless Steel, (280) 1" O.D. x 16 BWG, 75FV @...
Cleveland, TXEXCHANGERS 113473
Used estimated 300 sq. ft. Vertical 304L Stainless Steel Heat Exchanger. Mfg. by Southern Heat Exchanger in 1990. (96) 3/4" O.D. x 16 BWG Tubes. Shell Rated 150 psi @ -13 to 302 deg. F. Tubes Rated 150 psi @ -13 ...
Cleveland, TXEXCHANGERS 92404
- Manufacturer: HEBELER CORP, FOR APV CREPACO
PLATE AND FRAME HEAT EXCHANGER; MFG. BY HEBELER CORP, FOR APV CREPACO IN 1996; MAX WORKING PRESSURE 225 PSI @ 200 DEG. F.; MINIMUM -20 DEG. F. @ 225 PSI; PLATE PACK, 166, 40" H X 19" W; OVERALL DIMENSIONS 5' HIGH...
Cleveland, TXEXCHANGERS 107540
- Manufacturer: JOSEPH OAT CORPORATION
UNUSED SPENT FUEL COOLING STAINLESS STEEL HEAT EXCHANGER; NUCLEAR GRADE; MFG. BY JOSEPH OAT CORPORATION IN 2012;
Cleveland, TXEXCHANGERS 114492
Used 50 sq. ft. exchanger. Mfg. by Alabama Heat Exchanger in 2007. Carbon steel shell, 100FV @ 400 deg. F. (24) 3/4" OD tubes, 316L stainless steel, 100FV @ 400 deg. F. 6" diameter x 10'0" tube length.
Cleveland, TXEXCHANGERS 114486
Used 50 sq. ft. exchanger. Mfg. by Alabama Heat Exchanger in 2007. Carbon steel shell, 100FV @ 400 deg. F. (24) 3/4" OD tubes, 316L stainless steel, 100FV @ 400 deg. F. 6" diameter x 10'0" tube length.
Cleveland, TXEXCHANGERS 113092
"As Is, Where Is" Used Karbate Poly Bloc Heat Exchanger Phenolic Impregnated. Model #PBC24-20PU-1-2. Built in 2016.
Cleveland, TXEXCHANGERS 114746
Unused 327 sq. ft. heat exchanger. Mfg. by Fabsco shell and Tube in 2023. 1.1 Design duty (MMBTU/Hr). Shell Design Rating: 400/FV psi @ 300 deg. F. Tube Design Rating: 310 psi @ 150 deg. F. Shell mawp 415/FV psi...
Cleveland, TXEXCHANGERS 114741
Unused 284 sq. ft. Horizontal heat exchanger. Mfg by Fabsco Shell and Tube in 2023.. 2.32 Design duty (MMBTU/Hr). Shell Design Rating: 95/FV psi @ 300 deg. F. Tube Design Rating: 120 psi @ 150 deg. F. Shell mawp ...
Cleveland, TXEXCHANGERS 114749
Unused 112 sq. ft. heat exchanger. Mfg. by Fabsco Shell and Tube in 2023. 0.203 Design duty (MMBTU/Hr). Shell Design Rating: 425/FV psi @ 300 deg. F. Tube Design Rating: 330 psi @ 150 deg. F. Shell mawp 430/FV p...
Cleveland, TX