Building Filters

Efficient and Reliable Unattended Substation System | Factory Direct Pricing
Unattended Substation System - A reliable factory-produced solution for efficient management and operation of electrical substations. Enhance productivity with our innovative technology.
Beijing, China
GF1060 Laboratory Current Transformer Test System
The GF1060 current transformer test system is suitable for the calibration of traditional electromagnetic current transformers and electronic current transformers with small voltage output. The GF1060 current tra...
Beijing, China
FU-16 economic 333mv mini split core current transformer for meter
The model FU-16 split core ct is a 16mm diameter mini split-core current transformer offers 333mV, 100mV-2V and 10mA-200mA at secondary from sensed primary current (0-200A).
Beijing, China
FU160 3000/5a busbar split core type current transformer
The model FU160 is a bus bar split core current transformer. Busbar type split core current transformer also called split core current transformer or openable current transformer.
Beijing, China
FU-32 200/5a indoor clamp on split core current transformer ct
The model FU-32 split core ct is a 32mm diameter split-core current transformer offers 333mV, 100mV-2V and 10mA-200mA, 1A or 5A at secondary from sensed primary current (0-600A). This is an economic split core cu...
Beijing, China
FU-100 500/5A ring core AC clamp on open current transformer
The Model Fu-100 CLMP TYPE CT is a Split-Core Current Transformer Offers 333mv, 100MV-2V and 10mA-500MA, 1A or 5A at Secondary from Senset Primary (0-3000A). T His model fu-100 split core ct is 100MM diameter.
Beijing, China
FU120 low voltage bus bar type split core current transformer
The model FU120 is a bus bar split core current transformer. Busbar type split core current transformer also called split core current transformer or openable current transformer.
Beijing, China
FU-80 low cost indoor single phase split core current transformer
The model FU-80 is a split-core current transformer offers 333mV, 100mV-2V and 10mA-500mA ,1A or 5A at secondary from sensed primary current (0-1200A). This model has three diameter version (30mm, 55mm and 80mm),...
Beijing, China
LZCG530-10 11KV cast epoxy resin straight-through current transformer
The model LZCG530-10 series straight-through ct is a ring type resin casting 0.2s current transformer. It is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV ...
Beijing, China
lzck-120 outdoor 120mm window ip67 split core ct transformer
The model LZCK-120 outdoor split core current transformer are applicable for AC power system 35kV and measurement of current of power supply equipment The model LZCK-120 outdoor split core current transformer are...
Beijing, China
20KV Class Three Phase Oil-Immersed Distribution Transformer
: 300 Set/Sets per Month 20kv 600kva copper core distribution power transformer price Wooden case or according to customer’s requirements 20kv 600kva copper core distribution power transformer price Compared with...
Beijing, China
LZCK310-10 400/5a cheap split core cast resin current transformer
The model LZCK310-10 is a window type resin casting split core current transformer. Some clients also called it as TTCC. This model can be used both for measurement and microcomputer protection of electrical equi...
Beijing, China
LZCK-80 Ip68 outdoor waterproof high accuracy 0.5s split core current transformer
The model LZCK-80 IP68 outdoor split core current transformer are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection....
Beijing, China
LZCT722-10 electrical cast resin zct zero sequence current transformer
LZCT722-10 zero sequence current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.
Beijing, China
LMCK185-10 IP65 waterproof split core outdoor current transformer
The model LMCK185-10 series outdoor split core ct are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection.
Beijing, China