HCN 3E 30 F Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0 – 30 ppm Sensitivity Range: 60 nA/ ppm ± 15 nA/ ppm Zero Current at 20°C: < ± 15 nA Resolution at 20°C: < 0.2 ppm Bias Potential: 0mV Linearity: < 5% full scale Response Time at 20°C: t50 < 25 ...
Brescia, ItalyHCN 2E 30 F Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0 – 30 ppm Sensitivity Range: 30 nA/ ppm ± 15 nA/ ppm Zero Current at 20°C: < ± 5 nA Resolution at 20°C: < 0.2 ppm Bias Potential: not required Linearity: < 5% full scale Response Time at 20°C t5...
Brescia, ItalyDecca SKY3000
- Manufacturer: Decca
Rugged and durable The instrument can effectively resist a three-meter drop The protection level of the instrument reaches IP67 The instrument has passed the EMC anti-static interference test and can work normall...
$550 USDShenzhen, ChinaDECCA DC-SKY3000
- Manufacturer: Decca
Phosphine Gas Detector Measure PH3 0 to 5ppm 20ppm 2000ppm 3000ppm For Pest Control Fumigation Phosphine ph3 gas detector Product Advantage: Rugged and durable 1. The instrument can effectively resist a three-met...
$600 USDShenzhen, ChinaH2 3E 1% Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0–10000 ppm Sensitivity Range: 10 nA/ppm ± 5 nA/ppm Zero Current at 20°C: < ± 250 nA Resolution at 20°C: < 20 ppm Bias Potential: 0 V Linearity: < 5% full scale Response Time at 20°C: t50 < 40 s ...
Brescia, ItalyNH3 3E 500 SE Tecnosens
- Manufacturer: Tecnosens
Amperometric 3 electrode sensor cell Measuring Range: 0–500 ppm Sensitivity Range: 35nA/ppm ± 15nA/ppm Zero Current at 20°C: <± 100nA, typically 40nA Bias Potential: 0 mV Linearity: <10% full scale Response Time ...
Brescia, ItalyO3 3E 1 F Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0–1 ppm Sensitivity Range: 450 +/- 150 nA/ppm (negative signal) Zero Current at 20°C: < ± 10 nA Resolution at 20°C: < 0.03 ppm Bias Potential: 0 mV Linearity: < 10% full scale Response Time at 20...
Brescia, ItalyCOCl2 3E 1 Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0–1 ppm Sensitivity Range: 650 nA/ppm ± 150 nA/ppm Zero Current at 20°C: < ± 10 nA Resolution at 20°C: < 0.02 ppm Bias Potential: 0 mV Linearity: < 10% full scale Response Time at 20°C: t50 < 60 ...
Brescia, ItalyHCl 3E 30 Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0-30 ppm Sensitivity Range: 140 nA/ppm ± 60 nA/ppm Zero Current at 20°C: < ± 100 nA Resolution at 20°C: < 0.7 ppm Bias Potential: 200 mV Linearity: < 5% full scale Response Time at 20°C: t50 < 30...
Brescia, ItalyH2 3E 4% Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0-4% (100% LEL) Sensitivity Range: 1 nA/ppm ± 0.5 nA/ppm Zero Current at 20°C: < ± 100 nA Resolution at 20°C: < 100 ppm Bias Potential: 0 mV Linearity: < 10% full scale Response Time at 20°C: t50...
Brescia, ItalyDecca SKY8000
- Manufacturer: Decca
O2 CO2 N2 Gas Analyzer Food Bag Headspace Gas Analyzer Oxygen Carbon Dioxide Nitrogen Data Logger Printer SKY8000 series gas analyzer is a data collector which can quickly acquire and analyze gas concentration co...
$5,000 USDShenzhen, ChinaNO2 3E 50 Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0–50 ppm Sensitivity Range: 200 nA/ppm ± 40 nA/ppm (negative signal) Zero Current at 20°C: < ± 20 nA Resolution at 20°C: < 0.1 ppm Bias Potential: 0 mV Linearity: < 5% full scale Response Time at...
Brescia, ItalyCO 3E 300 Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0-500 ppm Sensitivity Range: 70 nA/ppm �� 20 nA/ppm Zero Current at 20��C: < 150 nA Resolution at 20��C: < 3 ppm Bias Potential: 0 mV Linearity: < 5% full scale Response Time at 20��C: t50 < 10 s...
Brescia, ItalyCl2 3E 10 Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0-10 ppm; typically: 0–5 ppm Sensitivity Range: 450 nA/ppm ± 200 nA/ppm (negative current) Zero Current at 20°C: < ± 20 nA Resolution at 20°C: < 0.05 ppm Bias Potential: 0 mV Linearity: < 5% full...
Brescia, ItalyNH3 3E 5000 SE Tecnosens
- Manufacturer: Tecnosens
Amperometric 3 electrode sensor cell Measuring Range: 0–5000 ppm Sensitivity Range: 4 nA/ppm ± 2 nA/ppm Zero Current at 20°C: <± 100 nA, typically 40 nA Resolution at 20°C <50 ppm, typically 20 ppm Bias Potential...
Brescia, Italy