EXCHANGERS 113357
Used 7.9 sq. ft. Vertical Plate/Block Exchanger, Mfg by Alfa Laval in 2015. (30) Plates Compabloc, Model CP15-H-30. Type Plate/Block. Previous Service: Hexanol Mix Tank Trim Heater.
Cleveland, TXEXCHANGERS 114590
Unused 377.9 sq. ft. plate exchanger. Mfg. by Alfa Laval in 2023. MAWP: 150/FV psig @ 356 deg. F. MDMT: 150/FV psig @ -20 deg. F. Model T21-MFG. A-Dim 183 mm with (40) 0.6 mm plates.
Cleveland, TXEXCHANGERS 95061
- Manufacturer: SWECOMEX
KELLOGG #108-C UNUSED BFW EXCHANGER; BUILT FOR 1500 TPD KELLOGG AMMONIA PLANT; MFG. BY SWECOMEX IN 1988; 999MM X 6035 MM; 335M2; SHELL: 10.5 KG/CM @ 280 DEG. C.; TUBES 10.5 KG/CM @ 93 DEG. C.;
Cleveland, TXEXCHANGERS 113770
Used 458 sq. ft. Vertical Exchanger. Mfg. by Doyle & Roth in 1998. 30" diameter x 12'0" F/F. Shell: Carbon Steel, FV/130 psi @ 350 deg. F. Tubes: 304L Stainless Steel, 100 psi @ 350 deg. F.
Cleveland, TXEXCHANGERS 114591
Unused 636.5 sq. ft. plate exchanger. Mfg. by Alfa LavaL in 2023. MAWP 150/FV psig @ 356 deg. F. , MDMT -20 deg. F. @ 150/FV psig, Model #T21-MFG. A-Dim 302 mm with (66) 0.6 mm plates.
Cleveland, TXEXCHANGERS 114586
Unused 1999.1 sq. ft. plate exchanger. Mfg. by Alfa Laval in 2023. MAWP: 150/FV psig @ 200 deg. F. MDMT: 150/FV psig @ -20 deg. F. Model T21-MFG. A-Dim 949 mm with (205) 0.6 mm plates.
Cleveland, TXEXCHANGERS 114589
Unused 377.9 sq. ft. plate exchanger. Mfg. by Alfa Laval in 2023. MAWP: 150/FV psig @ 356 deg. F. MDMT: 150/FV psig @ -20 deg. F. Model T21-MFG. A-Dim 183 mm with (40) 0.6 mm plates.
Cleveland, TXEXCHANGERS 114549
Used 225 sq. ft. vertical exchanger. Mfg. by Perry Products in 2015. 12" diameter x 11'0" F/F. Shell, tubes and heads all 304L stainless steel. 100 psi @ 320 deg. F. shell. 75FV psi @ 320 deg. F. tubes. (104) 3/4...
Cleveland, TXEXCHANGERS 113761
Used 1448 sq. ft. double diameter horizontal exchanger. Mfg. by Perry Products in 1999. 26"/36" diameter x 18'0" F/F. Shell: 304LSS 100 psi @ 350 deg. F. Tubes: 304LSS 100 psi @ 350 deg. F. (444)-3/4" O.D. x 18 BWG.
Cleveland, TXEXCHANGERS 113776
Used 375 sq. ft. Exchanger. Mfg. by Gaspar in 2005. 14" diameter x 20'0" F/F. Shell: Carbon Steel, FV/123 psi @ 350 deg. F. Tubes: Hastelloy C 276, FV/123 psi @ 350 deg. F. (96) 3/4" O.D. x .065".
Cleveland, TXEXCHANGERS 113771
Used 745 sq. ft. Horizontal Exchanger. Mfg. by Manning & Lewis in 1999. 30" diameter x 12'0" F/F. Shell: Carbon Steel, 140 psi @ 350 deg. F. Tubes: 304L Stainless Steel, 110 psi @ 350 deg. F. (633) 3/4" O.D. x 16...
Cleveland, TXEXCHANGERS 113775
Used 375 sq. ft. Exchanger. Mfg. by Gaspar in 2005. 14" diameter x 20'0" F/F. Shell: Carbon Steel, FV/123 psi @ 350 deg. F. Tubes: Hastelloy C 276, FV/123 psi @ 350 deg. F. (96) 3/4" O.D. x .065".
Cleveland, TXEXCHANGERS 112799
Used 12,580 sq. ft. plate exchanger. Mfg. by Alfa Laval, Inc. in 2012. Model #TL35-BFD. Previous Service: Venturi scrubber pump around cooler. (2)14" inlets & (2) 14" outlets. (811) plates x .02" thick. NBRP Clip...
Cleveland, TXEXCHANGERS 113777
Used 560 sq. ft. Vertical Exchanger. Mfg. by Gaspar in 2005. 18" diameter x 16'0" F/F. Shell: Carbon Steel, 123 psi @ 350 deg. F. Tubes: Hastelloy C 276, 123 psi @ 350 deg. F. (178) 3/4" O.D. x .065"., Heads are ...
Cleveland, TXEXCHANGERS 114443
Used 270 sq. ft. solvent recovery still horizontal exchanger. Mfg. by Perry Products. 8'0" F/F. (206)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 334 deg. F. Tubes 304 stainless steel, 44FV psi @ 334 de...
Cleveland, TX