EXCHANGERS 113515
used
Used 930 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 18" diameter x 20'0" F/F. Shell: Carbon Steel, 75FV psi @ 250 deg. F. Tubes: 316L Stainless Steel, (237) .75" O.D. x 16 BWG, 75FV...
Cleveland, TXEXCHANGERS 113512
used
Used 706 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 38" diameter x 6'0" F/F. Shell: Carbon Steel, 75FV psi @ 300 deg. F. Tubes: 316L Stainless Steel, (300) 1.5" O.D. x 16 BWG, 75FV ...
Cleveland, TXEXCHANGERS 102852
used
- Manufacturer: OHMSTEDE
FRESH WATER COOLER; SHELL MFG BY OHMSTEDE IN 1995; BUNDLE IN 2007; HEAD MFG. BY GULF COAST HEAT EXCHANGER IN 2001;
Cleveland, TXEXCHANGERS 113516
used
Used 733 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 24" diameter x 10'0" F/F. Shell: Carbon Steel, 75FV psi @ 300 deg. F. Tubes: 316L Stainless Steel, (280) 1" O.D. x 16 BWG, 75FV @...
Cleveland, TXEXCHANGERS 113473
used
Used estimated 300 sq. ft. Vertical 304L Stainless Steel Heat Exchanger. Mfg. by Southern Heat Exchanger in 1990. (96) 3/4" O.D. x 16 BWG Tubes. Shell Rated 150 psi @ -13 to 302 deg. F. Tubes Rated 150 psi @ -13 ...
Cleveland, TXEXCHANGERS 113760
used
Used 1957 sq. ft. vertical plate exchanger. Mfg. by Alfa Laval in 2016. Carbon Steel Frame and Alloy Plates. Model #T20-MFG.
Cleveland, TXEXCHANGERS 107540
used
- Manufacturer: JOSEPH OAT CORPORATION
UNUSED SPENT FUEL COOLING STAINLESS STEEL HEAT EXCHANGER; NUCLEAR GRADE; MFG. BY JOSEPH OAT CORPORATION IN 2012;
Cleveland, TXEXCHANGERS 114492
used
Used 50 sq. ft. exchanger. Mfg. by Alabama Heat Exchanger in 2007. Carbon steel shell, 100FV @ 400 deg. F. (24) 3/4" OD tubes, 316L stainless steel, 100FV @ 400 deg. F. 6" diameter x 10'0" tube length.
Cleveland, TXEXCHANGERS 114486
used
Used 50 sq. ft. exchanger. Mfg. by Alabama Heat Exchanger in 2007. Carbon steel shell, 100FV @ 400 deg. F. (24) 3/4" OD tubes, 316L stainless steel, 100FV @ 400 deg. F. 6" diameter x 10'0" tube length.
Cleveland, TXEXCHANGERS 113092
used
"As Is, Where Is" Used Karbate Poly Bloc Heat Exchanger Phenolic Impregnated. Model #PBC24-20PU-1-2. Built in 2016.
Cleveland, TXEXCHANGERS 112783
used
Previous Service: Feed gas saturator, Used 3074 sq. ft. heat exchanger. Manufactured by Cust-O-Fab in 1994.
Cleveland, TXEXCHANGERS 113349
used
Used 2,300 sq. ft. Vertical Heat Exchanger, Mfg by Mason in 2015. Previous Service: Flash Tank #2 Surface Condenser.
Cleveland, TXEXCHANGERS 114248
used
Previously Utilized in an API Facility. Used Condenser for K-2407 / R-2408; 340 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel tubes MOC. 90 psi.
Cleveland, TXEXCHANGERS 114247
used
Previously Utilized in an API Facility. Used Condenser for K-2405 / R-2406; 92 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel tubes MOC. 90 psi.
Cleveland, TXEXCHANGERS 113316
used
Used Approximately 400 Sq. Ft. Plate Heat Exchanger. Mfg. by APV in 2009. Model N34 M-11. .5mm Thick Plates.
Cleveland, TX