Building Filters
- Trusted Seller
2009 PROLECGE PROLEC 1500 kVA Oil Filled Transformer, 4160 pri. volts, 600Y/346 sec. volts
- Manufacturer: PROLECGE
Kva: 1500 kVA | Primary voltage: 4160 volts | Secondary voltage: 600/346 volts | Phase: 3-phase | Transformer type: Distribution Transformer | Auto vs isolation: Isolation | Oil vs dry: Oil | Made in: MEXICO | F...
- Trusted Seller
2009 GENERAL ELECTRIC PROLEC 3000/3990 kVA Oil Filled Transformer, 4160 pri. volts, 600/346 sec. volts
- Manufacturer: GE
Kva: 3000/3990 kVA | Primary voltage: 4160 volts | Secondary voltage: 600/346 volts | Phase: 3-phase | Transformer type: Distribution Transformer | Auto vs isolation: Isolation | Oil vs dry: Oil | Made in: MEXIC...
- Trusted Seller
1979 FERRANTI-PACKARD 1500 kVA Transformer, 6600 pri. volts, 550Y/317 sec. volts
- Manufacturer: Ferranti Packard Limited
Overview: Applications: Industrial power distribution, mining operations, substations, and medium-scale electrical systems requiring reliable medium-voltage transformation.
- Trusted Seller
1979 FERRANTI-PACKARD 6000 kVA Transformer, 6600 pri. volts, 550Y/317 sec. volts
- Manufacturer: Ferranti Packard Limited
Overview: Applications: Industrial power distribution, substations, and large-scale electrical systems requiring reliable medium-voltage transformation.
- Trusted Seller
2009 GENERAL ELECTRIC PROLEC 3000/3990 kVA Oil Filled Transformer, 4160 pri. volts, 600/346 sec. volts
- Manufacturer: GE
Kva: 3000/3990 kVA | Primary voltage: 4160 volts | Secondary voltage: 600/346 volts | Phase: 3-phase | Transformer type: Distribution Transformer | Auto vs isolation: Isolation | Oil vs dry: Oil | Made in: MEXIC...
- Trusted Seller
2014 DELTA E-CP3C7500 S013192-001
- Manufacturer: Delta
Kva: 7500/10000 kVA | Primary voltage: 13200 volts | Secondary voltage: 4160/2400 volts | Phase: 3-phase | Transformer type: Power Transformer | Auto vs isolation: Isolation | Oil vs dry: Dry | Enclosure type: N...
- Trusted Seller
HAMMOND POWER SOLUTIONS INC. 176197
- Manufacturer: Hammond
Transformer Specifications: Kva: 1000 | Primary voltage: 4160 volts | Secondary voltage: 600/347 volts | Phase: 3-phase | Transformer type: Substation Transformer | Auto vs isolation: Isolation | Oil vs dry: Dry ...
- Trusted Seller
2014 DELTA E-CP3C7500 S013212-001
- Manufacturer: Delta
Kva: 7500/1000 kVA | Primary voltage: 13200 volts | Secondary voltage: 4160/2400 volts | Phase: 3-phase | Transformer type: Power Transformer | Auto vs isolation: Isolation | Oil vs dry: Dry | Enclosure type: Ne...
- Trusted Seller
METALEC 04-7268-0B
- Manufacturer: METALEC
Transformer Specifications: Unit Manufacturer Specifications:
- Trusted Seller
2017 BOUNDARY ELECTRIC Outdoor Portable Substation w/ 1000 kVA Transformer, 4160V HV, 600Y/346V LV
- Manufacturer: BOUNDARY ELECTRIC
Transformer Specifications: Unit Manufacturer Specifications:
- Trusted Seller
METALEC Underground Substation w/ 800 kVA Transformer, 4160V HV, 600Y/346V LV
- Manufacturer: METALEC
Transformer Specifications: Unit Manufacturer Specifications:
- Trusted Seller
2001 PIONEER TRANSFORMERS G2112B1413
- Manufacturer: PIONEER TRANSFORMERS
Connection: HV: Delta, LV: Wye Full wave impulse level: HV: 125 kV, LV: 45 kV
- Trusted Seller
2001 PIONEER TRANSFORMERS G2112B1413
- Manufacturer: PIONEER TRANSFORMERS
Connection: HV: Delta, LV: Wye Full wave impulse level: HV: 125 kV, LV: 45 kV
- Trusted Seller
2001 PIONEER TRANSFORMERS G2112B1411
- Manufacturer: PIONEER TRANSFORMERS
Connection: HV: Delta, LV: Wye Full wave impulse level: HV: 125 kV, LV: 60 kV
- Trusted Seller
2016 BOUNDARY ELECTRIC Outdoor Portable Substation w/ 1000 kVA Transformer, 4160V HV, 600Y/346V LV
- Manufacturer: BOUNDARY ELECTRIC
Transformer Specifications: Unit Manufacturer Specifications: