Building Filters
EXCHANGERS 114721
Unused 767 sq. ft. heat exchanger. Mfg. by Wuxi chemical Equipment in 2023. 1.928 Design duty (MMBTU/Hr). Shell Design Rating: 150/FV psig @ 300/300 deg. F. Tube Design Rating: 120 psig @ 150 deg. F. Shell mawp ...
Cleveland, TXEXCHANGERS 114742
Unused 284 sq. ft. Horizontal heat exchanger. Mfg by Fabsco Shell and Tube in 2023.. 2.32 Design duty (MMBTU/Hr). Shell Design Rating: 95/FV psi @ 300 deg. F. Tube Design Rating: 120 psi @ 150 deg. F. Shell mawp ...
Cleveland, TXEXCHANGERS 112851
Used 1640 sq. ft. U-Tube exchanger. Mfg. by Energy Exchanger Company in 2011. Previous Service: Wastewater Cooler.
Cleveland, TXEXCHANGERS 114743
Unused 3181 sq. ft. Horizontal heat exchanger. 10.18 Design duty (MMBTU/Hr). Mfg. by Fabsco Shell and Tube in 2023. Shell Design Rating: 295/FV psi @ 310 deg. F. Tube Design Rating: 230 psi @ 150 deg. F. Shell m...
Cleveland, TXEXCHANGERS 114737
Unused 1,049 sq. ft. heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 5.1 Design duty (MMBTU/Hr). Shell Design Rating: 250/FV psig @ 550 deg. F. Tube Design Rating: 325/FV psig @ 700 deg. F. Shell mawp 27...
Cleveland, TXEXCHANGERS 114739
Unused 850 sq. ft. horizontal heat exchanger. 7.1 x 1.1 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. Shell Design Rating: 550/FV psig @ 475 deg. F. Tube Design Rating: 425/FV psig @ 65...
Cleveland, TXEXCHANGERS 114713
Unused 569 sq. ft. horizontal heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 1.625 Design duty (MMBTU/Hr). Shell Design Rating: 200/FV psig @ 300 deg. F. Tube Design Rating: 155 psig @ 300 deg. F. She...
Cleveland, TXEXCHANGERS 112852
Used 3007 sq. ft. U-Tube exchanger. Mfg. by Energy Exchanger Company. Previous Service: Makeup Water Trim Heater.
Cleveland, TXEXCHANGERS 114756
Unused 110 sq. ft. heat exchanger. 4.9 Design duty (MMBTU/Hr). Shell: 174FV psi @ 428 deg. F. Tubes: 174FV psi @ 428 deg. F.;Oil/Steam heat exchanger. Nitrogen Purge
Cleveland, TXEXCHANGERS 114732
Unused 493 sq. ft. horizontal heat exchanger. 5.39 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. . Shell Design Rating: 180/FV psig @ 320 deg. F. Tube Design Rating: 232/FV psig @ 430 ...
Cleveland, TXEXCHANGERS 114729
Unused 168 sq. ft. horizontal heat exchanger. 0.443 Design duty (MMBTU/Hr). Mfg. by The Anup Eng. (India) in 2022. . Shell Desing Rating: 105/FV psig @ 300/300 deg. F. Tube Design Rating: 120/FV psig @ 150/300 d...
Cleveland, TXEXCHANGERS 102479
- Manufacturer: CO A S T
MFG. BY CO. A.S.T. IN 1992; 253.8 SQM 316L SS TUBE HEAD; CS SHELL VERTICAL HEAT EXCHANGER (RE-BOILER); 9000MM LENGTH; 2300MM WIDTH; 2000MM HEIGHT; DESIGN PRESSURE TUBE SIDE 22 BAR @ 300 DEG. C.; SHELL 8 BAR @ 2...
Cleveland, TXEXCHANGERS 114544
Used 603 sq. ft. vertical exchanger. Mfg. by Perry Products in 2012. 16" diameter x 16'0" F/F. Shell, tubes and heads 304 stainless steel. 75FV @ 300 deg. F. shell. 75FV @ 300 deg. F. tubes. (192) 3/4" O.D. x 18 GA.
Cleveland, TXEXCHANGERS 114546
Used 75 sq. ft. vertical exchanger. Mfg. by Yula in 2018. 6" diameter x 8'0" F/F. Shell is 304L stainless steel, tubes and heads are 316L stainless steel. 150FV @ 400 deg. F. shell. 150FV @ 400 deg. F. tubes. (...
Cleveland, TXEXCHANGERS 112952
Used 500 sq. ft. vertical heat exchanger. Mfg. by Energy Exchanger Company in 2012. Previous Service: Wastewater Ammonia Purifier Reboiler.
Cleveland, TX