EXCHANGERS 114440
used
Used 118 sq. ft. concentration vessel horizontal exchanger. Mfg. by Perry Products. 10" diameter x 8'0" F/F. (121)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV...
Cleveland, TXEXCHANGERS 114124
used
Used 832 Sq Ft Vertical Shell and Tube heat exchanger. Manufactured by Rubicon in 1998. Carbon Steel Shell rated 200 PSI @ 450 deg. F. Hastelloy C276 Tubes rated 50 PSI/FV @ 350 deg. F. 222-1"OD x 16 BWG tubes 14...
Cleveland, TXEXCHANGERS 114437
used
Used 166 sq. ft. ring closure reactor horizontal exchanger. Mfg. by Perry Products. 12" diameter x 8'0" F/F. (127)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV...
Cleveland, TXEXCHANGERS 113207
used
Used 75 Estimated Sq. Ft. 304L Stainless Steel Vertical Plate Heat Exchanger. Mfg. by APV in 2015. With Carbon Steel Frame and 304L Stainless Steel Plates. Model #M-10. Rated mawp FV/150 psi @ 329 deg. F. mdmt -...
Cleveland, TXEXCHANGERS 112851
used
Used 1640 sq. ft. U-Tube exchanger. Mfg. by Energy Exchanger Company in 2011. Previous Service: Wastewater Cooler.
Cleveland, TXEXCHANGERS 112852
used
Used 3007 sq. ft. U-Tube exchanger. Mfg. by Energy Exchanger Company. Previous Service: Makeup Water Trim Heater.
Cleveland, TXEXCHANGERS 102479
used
- Manufacturer: CO A S T
MFG. BY CO. A.S.T. IN 1992; 253.8 SQM 316L SS TUBE HEAD; CS SHELL VERTICAL HEAT EXCHANGER (RE-BOILER); 9000MM LENGTH; 2300MM WIDTH; 2000MM HEIGHT; DESIGN PRESSURE TUBE SIDE 22 BAR @ 300 DEG. C.; SHELL 8 BAR @ 2...
Cleveland, TX- Cleveland, TX
EXCHANGERS 113353
used
Used 30 sq. ft. Vertical Plate Exchanger, Mfg by Alfa Laval in 2015. .50 MM Plate Thickness, Model M6-MFG. EPDMP Clip On Plate Exchanger Gaskets. Previous Service: Hexanol Recovery Stripper Feed Heater.
Cleveland, TXEXCHANGERS 86923
used
- Manufacturer: CAMDEN ALLOY
NORTH BOTTOM HPA EXCHANGER; MFG. BY CAMDEN ALLOY IN 1980;
Cleveland, TXEXCHANGERS 113830
used
Used 3480 dq. ft. vertical Exchanger. Mfg. by Harliss Specialties Corp in 1987. Shell SA515 Gr 70, 3' 1.25" diameter X 15' long, 75 psi @ 150 deg. F. Tubes SA249 type 304 stainless steel, (1182) straight tubes, 3...
Cleveland, TXEXCHANGERS 100430
used
- Manufacturer: HEATRAN
CONVERTER FEED EFFLUENT EXCHANGER (1000 T/D NH3 PLANT); MFG. BY HEATRAN;
Cleveland, TXEXCHANGERS 93470
used
- Manufacturer: DOYLE & ROTH
EXTERNAL EXCHANGER AUX RX COOLER; MFG. BY DOYLE & ROTH IN 1990; SB626-B2 TUBES;
Cleveland, TXEXCHANGERS 98868
used
- Manufacturer: EFCO
KELLOGG #123-C; NH3 CONVERTER EFFLUENT/BFW EXCHANGER; MFG. BY EFCO IN 1999; SPECIAL ALL WELDED;
Cleveland, TXEXCHANGERS 114557
used
Used 250 sq. ft. horizontal exchanger. 24" diameter x 6'0" F/F. Shell, tubes and heads stainless steel.
Cleveland, TX