EXCHANGERS 114486
Used 50 sq. ft. exchanger. Mfg. by Alabama Heat Exchanger in 2007. Carbon steel shell, 100FV @ 400 deg. F. (24) 3/4" OD tubes, 316L stainless steel, 100FV @ 400 deg. F. 6" diameter x 10'0" tube length.
Cleveland, TXEXCHANGERS 113092
"As Is, Where Is" Used Karbate Poly Bloc Heat Exchanger Phenolic Impregnated. Model #PBC24-20PU-1-2. Built in 2016.
Cleveland, TXEXCHANGERS 114725
Unused 795 sq. ft. heat exchanger. Mfg. by The Anup Engineering Limited in 2022. 1.65 Design duty (MMBTU/Hr). Shell Design Rating: 105/FV psig @ 340/300 deg. F. Tube Design Rating: 120/FV psig @ 150/300 deg. F. ...
Cleveland, TXEXCHANGERS 114710
Unused 234 sq. ft. horizontal heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 3.6 Design duty (MMBTU/Hr). Shell Design Rating: 180/FV psig @ 430/300 deg. F. Tube Design Rating: 232/FV psig @ 430/400 deg...
Cleveland, TXEXCHANGERS 113889
Used 165 sq. ft. Tantalum 2.5% tubes, tube sheets, 316 Stainless Steel heads, 316 Stainless Steel shell, horizontal shell and tube heat exchanger. Shell side rated for 290/FV psi @ 400 degrees F. Tubes rated for ...
Cleveland, TXEXCHANGERS 113764
Used 424 sq. ft. Horizontal Exchanger. Mfg. by Perry Products in 1999. 14" diameter. Shell: Carbon Steel, 100 psi @ 350 deg. F. Tubes: 304L Stainless Steel, 100 psi @ 350 deg. F. With expansion joint.
Cleveland, TXEXCHANGERS 112798
Used 12,580 sq. ft. plate exchanger. Mfg. by Alfa Laval, Inc. in 2012. Model #TL35-BFD. Previous Service: Venturi scrubber pump around cooler. (2)14" inlets & (2) 14" outlets. (811) plates x .02" thick.
Cleveland, TXEXCHANGERS 114590
Unused 377.9 sq. ft. plate exchanger. Mfg. by Alfa Laval in 2023. MAWP: 150/FV psig @ 356 deg. F. MDMT: 150/FV psig @ -20 deg. F. Model T21-MFG. A-Dim 183 mm with (40) 0.6 mm plates.
Cleveland, TXEXCHANGERS 95061
- Manufacturer: SWECOMEX
KELLOGG #108-C UNUSED BFW EXCHANGER; BUILT FOR 1500 TPD KELLOGG AMMONIA PLANT; MFG. BY SWECOMEX IN 1988; 999MM X 6035 MM; 335M2; SHELL: 10.5 KG/CM @ 280 DEG. C.; TUBES 10.5 KG/CM @ 93 DEG. C.;
Cleveland, TXEXCHANGERS 113770
Used 458 sq. ft. Vertical Exchanger. Mfg. by Doyle & Roth in 1998. 30" diameter x 12'0" F/F. Shell: Carbon Steel, FV/130 psi @ 350 deg. F. Tubes: 304L Stainless Steel, 100 psi @ 350 deg. F.
Cleveland, TXEXCHANGERS 112783
Previous Service: Feed gas saturator, Used 3074 sq. ft. heat exchanger. Manufactured by Cust-O-Fab in 1994.
Cleveland, TXEXCHANGERS 113349
Used 2,300 sq. ft. Vertical Heat Exchanger, Mfg by Mason in 2015. Previous Service: Flash Tank #2 Surface Condenser.
Cleveland, TXEXCHANGERS 113316
Used Approximately 400 Sq. Ft. Plate Heat Exchanger. Mfg. by APV in 2009. Model N34 M-11. .5mm Thick Plates.
Cleveland, TXEXCHANGERS 108628
PREP TANK COOLER; 11.1 SQ. FT. PLATE HEAT EXCHANGER; MFG. BY ALFA LAVAL IN 2011; MODEL #TL3-PFG; NBRP GASKETS; PLATE THICKNESS .50MM;
Cleveland, TXEXCHANGERS 113042
Used 2200 Sq. ft. Zirconium Exchanger. Mfg. by Apex in 2012. Apex Model # Zr-28-288-2200-CS. 28.75" OD. 25'6.75" O.A.L. **Note: Requires one head, the exchanger was directly piped to tubesheet.
Cleveland, TX