Accuenergy Acuvim 3 Series Advanced Power Quality Meter with DIN rail mount, 5 A, AC/DC in Wilmington, NC, USA

Specifications

Condition
new
Voltage accuracy
0.1% reading, 10 to 400 VLN, 690 VLL
Current accuracy
0.1% reading:1 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 A
Frequency accuracy
1 mHz, 40 to 70 Hz
Active energy accuracy
IEC 62053-22 Class 0.1SANSI C12.20 Class 0.1
Power quality
IEC 6100-4-30 Class A, testing according to IEC 62586-2 (2017)
Safety
IEC/UL 61010-1:2010IEC/UL 61010-2-030:2010Overvoltage Category IIIMeasurement Category III
Voltage rms
IEC 61557-12 Class 0.1, 10 to 400 VLN, 690 VLL
Current rms
IEC 61557-12 Class 0.11 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 A
Frequency
1 mHz accuracy, 40 to 70 Hz, exceeds requirement of IEC 61557-12 Class 0.02
Power and power factor (for each phase and system)
Active power: IEC 61557-12 Class 0.1ReActive power: Exceeds requirement of IEC 61557-12 Class 1Apparent power: IEC 61557-12 Class 0.2Power factor: Exceeds requirement of IEC 61557-12 Class 0.5
Fundamental measurements
Line to neutral voltage RMSLine to line voltage RMSLine current RMSActive powerReactive powerApparent powerPower factor
Maximumimum/minimum
maximumimum/minimum of RMSPower and power factorsFundamental measurements records with timestamp
Demand
Algorithms: Block and rolling windowLog peak demand and peak demand timeCurrent demand for each phase and systemPer phase and system active power demand:Import/export/net/totalFour-quadrantPer phase and system reactive power demand:Import/export/net/totalFour-quadrantPer phase and system apparent power demand:TotalFour-quadrant
Energy (per phase and system)
Active energy, IEC 62053-22 Class 0.1S:Import/export/net/totalFour-quadrantReactive energy, IEC 62053-24 Class 0.5S:Import/export/net/totalFour-quadrantPer phase and systemApparent energy, IEC 61557-12 Class 0.2:TotalFour-quadrant
Tou energy and demand
For system import active energy, import reactive energy, and apparent energy:Up to 8 tariff ratesRecord maximumimum power demand of billing periodRecord current and up to 12 historic billing periods
Power quality measurements
Positive/negative/zero sequence for current and voltagePhase angle for current and voltageHarmonics magnitude and angle for current and voltage, up to 127thFlicker
Communication interfaces
2 x Ethernet ports (100BASE-TX) with IEEE1588 support: RJ45 connector, CAT5/5e/6/6a cable1 Wi-Fi (802.11 b/g/n 2.4 GHz)1 RS485 port: Baud rates of 2400 to 115,200, pluggable screw terminal connector1 USB-C port1 IRIG-B port
Time synchronization
NTPPTPIRIG-B
Serial port protocols
Modbus RTU
Ethernet port protocols
IPv4, IPv6, DHCP, DNSModbus TCP, DNP3 TCP, IEC 61850, SNMP, BACnet/IP, PMU (IEEE C37.118)Data post with E-mailFile download with
Power supply
50/60 Hz, 100 to 415 V AC/100 to 300 V DC
Ac voltage inputs
Accuracy range: 10 to 400 VLN, 690 VLLPickup: 5 VOverload: 1500 V AC continuously; 2500 V AC, 50/60 Hz 1 minuteMeasurement category: IIIFrequency range: 40 to 70 Hz (50/60 Hz nominal)
Ac current inputs
Nominal current: 1 or 5 AAccuracy range:1 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 APickup:1 A nominal: 0.5 mA5 A nominal: 2.5 mASurge: 20 A continuous, 50 A at 10 second/hour, 500 A at 1 second/hour
Input and output (meter base)
4 digital inputs:Input voltage range: 20 to 150 V AC/DCInput current (maximum): 2.5 mAStart voltage: 15 VStop voltage: 5 VPulse frequency (maximum): 100 Hz, 50% duty ratio (5ms ON and 5ms OFF)SOE resolution: 2ms1 digital output:Dry contactVoltage range: 30 V DCLoad current: 60 mA (maximum)Output frequency: 50 Hz, 50% duty ratio (20ms ON, 20ms OFF)Isolation voltage: 5000 V AC
I/o modules (up to 3, sold separately)
Digital input:Input voltage range 20 to 160 V AC/DCInput current (maximum) 2 mAStart voltage 15 VStop voltage 5 VPulse frequency (maximum) 100 Hz, 50% duty ratioSOE resolution 2msDigital output (DO) (Photo-MOS):Voltage range 0 to 250 V AC/DCLoad current 100 mA(maximum)Output frequency 25 Hz, 50% duty ratioIsolation voltage 2500 V ACRelay output (RO):Switching voltage (maximum) 250 V AC, 30 V DCLoad current 5 A(R), 2 A(L)Set time 10ms (maximum)Contact resistance 30 mΩ (maximum)Isolation voltage 2500 V ACAnalog output (AO):Output range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional)Accuracy 0.5%Temperature drift 50 ppm/°C typicalIsolation voltage 500 V DCOpen circuit voltage 15 VAnalog input (AI):Input range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional)Accuracy 0.2%Temperature drift 50 ppm/°C typicalIsolation voltage 500 V DC
Outlines standard
DIN 43700, ANSI C39.1Round or square, 3.6 x 3.6" (92 x 92 mm)
Ip degree of protection
IP 54: panel mount and touchscreen display, frontIP 30: panel mount rear, DIN rail mount, I/O modules
Temperature
Operating: -13 to 158°F (-25 to 70°C)Storage: -40 to 158°F (-40 to 70°C)
Pressure
Normal
Humidity
5 to 95% RH non-condensing
Altitude
9842.5' (3000 m)
Pollution degree
2
Location/mounting
Indoor use only
Immunity to fast transients
IEC 61000-4-4:Power, input/output, voltage/current circuits: ±4 kV (5 kHz)Communication: ±4 kV (5 kHz)
Immunity to ring waves
IEC 61000-4-12:Power, input/output, voltage/current circuits: 2.5 kVCommunication: 2.5 kV
Immunity to electrostatic discharge
IEC 61000-4-2:Contact discharge: ±4 kVAir discharge: ±8 kV
Immunity to voltage dips and interruptions
IEC 61000-4-11:70%, 20 ms0%, 100 ms
Immunity to power frequency and magnetic fields
IEC 61000-4-8:100 A/m, 1 minute1000 A/m, 3 seconds
Immunity to surges
IEC 61000-4-5:Power, voltage/current circuits: ±4 kVInput/output: 2 kVCommunication: 2 kV
Immunity to radiated fields
IEC 61000-4-3:80 to 1000 MHz: 10 V/m1 to 2.7 GHz: 3 V/m2.7 to 6.0 GHz: 1 V/m
Immunity to conducted disturbances
IEC 61000-4-6:150 kHz to 80 MHz: 10 V
Immunity to power frequency disturbances
IEC 61000-4-16:30 V: 1 minute300 V: 1 s
Immunity to damped oscillatory wave
IEC 61000-4-18:AC:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)1 kV (differential mode, 10 MHz)DC:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)1 kV (differential mode, 10 MHz)IO:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)
Radiated emissions
CISPR 32 Class B
Subcategory
Electricity
Listing ID
97218364

Description

The Acuvim 3 advanced power quality meters are engineered to provide high-precision power quality metering plus revenue grade, IEC Class 0.1S/ANSI C12.20 Class 0.1 (active energy) four-quadrant power monitoring. With support for synchrophasor applications, it can record real-time power quality disturbances, like dips, swells interruptions, unbalance, flicker, and transients as well as capture critical waveforms triggered by sub-second power quality events. Its enhanced Fast Log capture feature can generate and send reports, providing critical information to mitigate the impact of damaging power quality issues. Compact and robust, this advanced power quality meter features a wide range of flexible communication protocols plus an easy-to-use interface with advanced user management and security.
Features
Advanced single-point metering with revenue grade accuracy
Fast Log captures instantaneous power quality events and saves a report for future assessment

$2,300 USD

Manufacturer
Accuenergy
Model
Acuvim
Location
🇺🇸 Wilmington, NC, USA

Interested in this machine?

Seller Responsiveness:

5.0
Get Financing

Our financing partner can help you get fast, easy, and affordable financing for your equipment purchase