Specifications

Condition
new
Voltage
0.2%
Current
0.2%
Power
0.5%
Reactive power
0.5%
Apparent power
0.5%
Power demand
0.5%
Reactive power demand
0.5%
Apparent power demand
0.5%
Power factor
0.5%
Frequency
50/60Hz
Energy primary
0.5%
Energy secondary
0.5%
Reactive energy primary
0.5%
Reactive energy secondary
0.5%
Apparent energy primary
0.5%
Apparent energy secondary
0.5%
Harmonics
1.0%
Phase angle
2.0%
Unbalance factor
2.0%
Nominal current
5A /1A
Metering range
0~10A ac
Withstand
3250Vac, 50/60Hz for 1 minute
Burden
5W
Pickup current
0.1% of nominal
Accuracy
0.2% full scale
Nominal full scale
400Vac L-N, 690Vac L-L (+20%)
Input impedance
2Mohm per phase
Metering frequency
45Hz~65Hz
Pickup voltage
10Vac (30 Vac for Acuvim IIR/IIE/IIW)
Active (according to iec 62053-22)
Class 0.2s
(according to ansi c12.20)
Class 0.2s
Reactive (according to iec 62053-23)
Class 2
Metered value
Acuvim II: 31st harmonic
Universal
AC or DC
Operating range
20~60Vdc
Operation temperature
- 25°C to 70°C
Storage temperature
- 40°C to 85°C
Relative humidity
5% to 95% non-condensing
Measurement standard
IEC 62053-22; ANSI C12.20
Environmental standard
IEC 60068-2
Safety standard
IEC 61010-1, UL 61010-1
Emc standard
IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22
Outlines standard
DIN 43700, ANSI C39.1
Category
Item
Metering
Energy & Demand
Tou
Daylight Savings Time
Monitoring
Statistics
Others
Time
Option module
Communication
Subcategory
Electricity
Listing ID
97208506

Description

Power Quality is used to analyze the characteristics of the incoming electricity interacting with the electrical equipment and devices that use it. There are several different components which can be individually measured for an in-depth analysis of the overall power quality including; transient voltages and currents, individual waveform capture, harmonic distortion, sag and swell monitoring, frequency variations, and power factor. The Acuvim IIW series of power/energy meters allows building managers to remain proactive about power quality issues and avoid costly issues that spot-checking and power studies alone can miss. The Acuvim IIW meter features Modbus RS485 communication standard and can be upgraded to include Modbus TCP Ethernet, BACnet, Profibus, and a variety of other communication protocols and I/O expansions for added versatility.
The Acuvim IIW is able to time stamp the event that a voltage swell or dip had occurred. The meter can save up to 50,000 events.

$1,145 USD

Manufacturer
Accuenergy
Model
Acuvim IIW
Location
🇺🇸 Wilmington, NC, USA

Interested in this machine?

Seller Responsiveness:

5.0
Get Financing

Our financing partner can help you get fast, easy, and affordable financing for your equipment purchase