Accuenergy Acuvim IIW-D-5A-P1 Power/Energy Meter with Waveform Capture, LCD, 5 A/1 A input, 415 Vac/300 Vdc in Wilmington, NC, USA
New
Doubleclick to zoom in
Contact the seller for
additional photos and information.
Specifications
- Condition
- new
- Voltage
- 0.2%
- Current
- 0.2%
- Power
- 0.5%
- Reactive power
- 0.5%
- Apparent power
- 0.5%
- Power demand
- 0.5%
- Reactive power demand
- 0.5%
- Apparent power demand
- 0.5%
- Power factor
- 0.5%
- Frequency
- 50/60Hz
- Energy primary
- 0.5%
- Energy secondary
- 0.5%
- Reactive energy primary
- 0.5%
- Reactive energy secondary
- 0.5%
- Apparent energy primary
- 0.5%
- Apparent energy secondary
- 0.5%
- Harmonics
- 1.0%
- Phase angle
- 2.0%
- Unbalance factor
- 2.0%
- Nominal current
- 5A /1A
- Metering range
- 0~10A ac
- Withstand
- 3250Vac, 50/60Hz for 1 minute
- Burden
- 5W
- Pickup current
- 0.1% of nominal
- Accuracy
- 0.2% full scale
- Nominal full scale
- 400Vac L-N, 690Vac L-L (+20%)
- Input impedance
- 2Mohm per phase
- Metering frequency
- 45Hz~65Hz
- Pickup voltage
- 10Vac (30 Vac for Acuvim IIR/IIE/IIW)
- Active (according to iec 62053-22)
- Class 0.2s
- (according to ansi c12.20)
- Class 0.2s
- Reactive (according to iec 62053-23)
- Class 2
- Metered value
- Acuvim II: 31st harmonic
- Universal
- AC or DC
- Operating range
- 20~60Vdc
- Operation temperature
- - 25°C to 70°C
- Storage temperature
- - 40°C to 85°C
- Relative humidity
- 5% to 95% non-condensing
- Measurement standard
- IEC 62053-22; ANSI C12.20
- Environmental standard
- IEC 60068-2
- Safety standard
- IEC 61010-1, UL 61010-1
- Emc standard
- IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22
- Outlines standard
- DIN 43700, ANSI C39.1
- Category
- Item
- Metering
- Energy & Demand
- Tou
- Daylight Savings Time
- Monitoring
- Statistics
- Others
- Time
- Option module
- Communication
- Subcategory
- Electricity
- Subcategory 2
- Power and energy monitors
- Listing ID
- 97208500
Description
Power Quality is used to analyze the characteristics of the incoming electricity interacting with the electrical equipment and devices that use it. There are several different components which can be individually measured for an in-depth analysis of the overall power quality including; transient voltages and currents, individual waveform capture, harmonic distortion, sag and swell monitoring, frequency variations, and power factor. The Acuvim IIW series of power/energy meters allows building managers to remain proactive about power quality issues and avoid costly issues that spot-checking and power studies alone can miss. The Acuvim IIW meter features Modbus RS485 communication standard and can be upgraded to include Modbus TCP Ethernet, BACnet, Profibus, and a variety of other communication protocols and I/O expansions for added versatility.
The Acuvim IIW is able to time stamp the event that a voltage swell or dip had occurred. The meter can save up to 50,000 events.
$1,099 USD