Fluke 1748/B/EUS Three-Phase Power Quality Logger, EU/US version in Wilmington, NC, USA

Specifications

Condition
new
Voltage
Range: 42.5 to 69 Hz Maximum resolution: 0.01 Hz Intrinsic accuracy at reference conditions (% of reading +% of range): ±(0.1%)2
Auxiliary input
Range: ±10 V DC Maximum resolution: 0.1 mV Intrinsic accuracy at reference conditions (% of reading +% of range): ±(0.2% + 0.02%)
Voltage min/max
Range: 1000 V Maximum resolution: 0.1 V Intrinsic accuracy at reference conditions (% of reading +% of range): ±0.2 % of nominal input voltage
Current min/max
Range: Defined by accessory Maximum resolution: Defined by accessory Intrinsic accuracy at reference conditions (% of reading +% of range): ±(5% + 0.2%)
Thd on voltage
Range: 1000% Maximum resolution: 0.10% Intrinsic accuracy at reference conditions (% of reading +% of range): ± 2.5%
Thd on current
Range: 1000% Maximum resolution: 0.10% Intrinsic accuracy at reference conditions (% of reading +% of range): ± 2.5%
Voltage harmonics 2nd to 50th
Range: 1000 V Maximum resolution: 0.1 V Intrinsic accuracy at reference conditions (% of reading +% of range): ≥1 V: ±5% of reading, <1 V: ±0.05 V
Current harmonics 2nd to 50th
Range: Defined by accessory Maximum resolution: Defined by accessory Intrinsic accuracy at reference conditions (% of reading +% of range): ≥3% of current range: ±5% of reading, <3% of current range: ±0.15% of range
Flicker plt, pst
Range: 0 to 20 Maximum resolution: 0.01 Intrinsic accuracy at reference conditions (% of reading +% of range): 5%
Voltage range
100 to 500 V using safety plug input when powering from the measurement circuit 100 to 240 V MA-C8 and using standard power cord (IEC 60320 C7)
Power consumption
Maximum 50 VA (max. 15 VA when powered using MA-C8 adapter)
Efficiency
≥68.2% (in accordance with energy efficiency regulations)
Maximum no-load consumption
<0.3 W only when powered using IEC 60320 input
Mains power frequency
50/60 Hz ±15%
Battery
Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime
Typically 4 hours
Charging time
<6 hours
Resolution
16-bit synchronous sampling
Sampling frequency
10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input signal frequency
50/60 Hz (42.5 to 69 Hz)
Circuit types
1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies)
Data storage
Internal flash memory (not user replaceable)
Memory size
Typical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events
Measured parameters
Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Averaging interval
10 min for all parameters 2 hrs (long term Flicker PLT) 150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT)
Averaging time min/max values
Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms)
Interval
User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Measured parameter
Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation
Individual harmonics
2nd to 50th harmonic Grouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only
Interharmonics
1st to the 50th interharmonic
Total harmonic distortion
Calculated on 50 voltage harmonics
Events
Mains signaling, transients (low frequency)
Triggered recordings
RMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1/2 according to IEC 61000-4-30) Waveform of voltage and current up to 200 ms, 10/12 cycles Mains signaling: 10/12 cycle RMS recording of the configured frequencies up to 120 s
Inrush
RMS profile based on ½ cycle RMS steady state triggering
Flicker
In accordance with IEC 61000-4-15 and IEEE 1453
Mains signaling
Two user defined frequencies up to 3 kHz
Pq health
Summarizes power quality measurements in one table. Detailed data available for each parameter
En 50160
Compliance with standard
Programmable pq limits
Enables user defined limits for local standards compliance
Harmonics
IEC 61000-4-7: Class 1 IEEE 519 (short time and very short time harmonics)
Power quality
IEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device)
Power
IEEE 1459
Power quality compliance
EN 50160
Safety
General: IEC 61010-1: Pollution Degree 2 Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 1000 V Power Supply: Overvoltage Category IV, Pollution Degree 2 Li-ion Battery: IEC 62133
Usb-a
File transfer via USB flash drive, firmware updates, max. supply current: 120 mA
Wi-fi
File transfer and remote control via direct connection or Wi-Fi infrastructure
Bluetooth
Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or Wi-Fi/BLE adapter, check for availability)
Usb-mini
Data download device to PC
Number of inputs
2
Maximum input voltage
1000 Vrms, CF 1.7
Input impedance
10 MΩ
Bandwidth
42.5 Hz to 3.5 kHz
Scaling
1:1 and variable
Measurement category
1000 V CAT III/600 V CAT IV
Input voltage
Clamp input: 500/50 mVrms; CF 2.8 Rogowski coil input: 150/15 mVrms at 50 Hz, 180/18 mVrms at 60 Hz CF 4 all at nominal probe range
Range
1 to 150 A/10 to 1500 A with thin flexible current probe i17XX-flex1500 IP 24
Input range
0 to ± 10 V DC, or 0 to ± 1000 V DC (with optional adapter), 1 reading/s
Scale factor
Format: mx + b (gain and offset) user configurable
Displayed units
User configurable (7 characters, for example, °C, psi, or m/s)
Supported modules
Fluke Connect® 3000 series
Acquisition
1 reading/s
Operating temperature
-13 to 122°F (-25 to 50°C)
Storage temperature
Without battery: -13 to 140°F (-25 to 60°C) With battery: −4 to 122°F (-20 to 50°C)
Operating humidity
IEC 60721-3-3: 3K6: -13 to 86°F (-25 to 30°C): ≤100% 104°F (40°C): 55% 122°F (50°C): 35%
Operating altitude
6561.7' (2000 m) up to 13,123.4' (4000 m) derate to 1000 V CAT II/600 V CAT III/300 V CAT IV
Storage altitude
39,370.1' (12,000 m)
Enclosure
IEC 60529: IP50 IEC 60529: IP65 with IP65 rated voltage connector
Vibration
IEC 60721-3-3 /3M2
Electromagnetic compatibility (emc)
EN 61326-1: Industrial CISPR 11: Group 1, Class A IEC 61000-6-5 Power station environment Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Dimensions
9.1 x 7.1 x 2.1" (23 x 18 x 5.4 cm)
Weight
2.2 lbs (1 kg)
Tamper protection
Accept securing cables (max. Φ 6mm)
Subcategory
Electricity
Listing ID
97179376

Description

Get fast and easy access to the data you need to make real-time decisions about critical power quality and energy with this three-phase power quality logger.
Troubleshoot, quantify energy usage and perform quality of service surveys easier than ever
Get fast and easy access to the data you need to make real-time decisions about critical power quality and energy with this three-phase power quality logger.
Compact and rugged, this three-phase power quality logger is specifically for technicians and engineers who need the flexibility to troubleshoot, quantify energy usage and analyze power distribution systems. Fully compliant with international power quality standards such as IEC 61000-4-30 and capable of simultaneously logging up to 500 parameters while also capturing events, this unit helps uncover intermittent and hard-to-find power quality issues more easily than ever.

$11,941 USD

Manufacturer
Fluke
Model
1748/B/EUS
Location
🇺🇸 Wilmington, NC, USA

Interested in this machine?

Seller Responsiveness:

5.0
Get Financing

Our financing partner can help you get fast, easy, and affordable financing for your equipment purchase