6ES7412-2XG04-0AB0 CPU412-2, MPI/DP, 256KB in Shenzhen, Guangdong, China
New
Specifications
- Condition
- new
- Artikelnummer
- 6ES7412-2XG04-0AB0
- Firmware version
- V4.0
- Programming package
- STEP7 V5.2 SP1 HF3 or higher with HW update
- Cir synchronization time, basic load
- 100 ms
- Cir synchronization time, time per i/o slave
- 200 µs
- 24 v dc
- Yes
- From backplane bus 5 v dc, typ.
- 1 A
- From backplane bus 5 v dc, max.
- 1.2 A
- From backplane bus 24 v dc, max.
- Total current consumption of the components connected to the MPI/DP interfaces, but no more than 150 mA per interface
- Power loss, typ.
- 4.5 W
- Integrated (for program)
- 128 kbyte
- Integrated (for data)
- 128 kbyte
- Expandable
- No
- Expandable feprom
- Yes; with Memory Card (FLASH)
- Expandable feprom, max.
- 64 Mbyte
- Integrated ram, max.
- 256 kbyte
- Expandable ram
- Yes; with Memory Card (RAM)
- Expandable ram, max.
- 16 Mbyte
- Present
- Yes
- With battery
- Yes; all data
- Without battery
- No
- Backup current, typ.
- 350 µA
- Backup current, max.
- 890 µA
- Backup time, max.
- 226 d
- Feeding of external backup voltage to cpu
- 5 to 15 VDC
- For bit operations, typ.
- 0.1 µs
- For word operations, typ.
- 0.1 µs
- For fixed point arithmetic, typ.
- 0.1 µs
- For floating point arithmetic, typ.
- 0.3 µs
- Number, max.
- 512; DB 0 reserved
- Size, max.
- 64 kbyte
- Number of time alarm obs
- 2
- Number of delay alarm obs
- 2
- Number of time interrupt obs
- 2
- Number of process alarm obs
- 2
- Number of multicomputing obs
- 1
- Per priority class
- 24
- Additional within an error ob
- 1
- Number
- 8
- Adjustable
- Yes
- Lower limit
- 10 ms
- Upper limit
- 9 990 s
- Preset
- 120
- Retentive data area, total
- Total working and load memory (with backup battery)
- Retentivity available
- Yes; From MB 0 to MB 4095
- Retentivity preset
- MB 0 to MB 15
- Number of clock memories
- 8; 1 memory byte
- Adjustable, max.
- 8 kbyte
- Inputs
- 244 byte
- Outputs
- 244 byte
- Mpi/dp interface, inputs
- 2 kbyte
- Mpi/dp interface, outputs
- 2 kbyte
- Dp interface, inputs
- 4 kbyte; for each line that is operated in isochronous mode, i.e. to which an OB61 to 62 has been assigned, the distributed IO address areas are halved
- Dp interface, outputs
- 4 kbyte; for each line that is operated in isochronous mode, i.e. to which an OB61 to 62 has been assigned, the distributed IO address areas are halved
- Inputs, adjustable
- 4 kbyte
- Outputs, adjustable
- 4 kbyte
- Inputs, default
- 128 byte
- Outputs, default
- 128 byte
- Consistent data, max.
- 244 byte
- Access to consistent data in process image
- Yes
- Number of subprocess images, max.
- 15
- Inputs, of which central
- 2 048
- Outputs, of which central
- 2 048
- Expansion devices, max.
- 21; of which 6 ER with K-bus
- Connectable ops
- 15 without message processing, 8 with message processing
- Multicomputing
- Yes; 4 CPUs max. (with UR1 or UR2)
- Number of connectable ims (total), max.
- 6
- Number of connectable im 460s, max.
- 6
- Number of connectable im 463s, max.
- 4; IM 463-2
- Integrated
- 2
- Via im 467
- 4
- Via cp
- 10; CP 443-5 Extended
- Mixed mode im cp permitted
- No; IM 467 cannot be used jointly with CP 443-5 Ext.
- Via interface module
- 0
- Number of pluggable s5 modules (via adapter capsule in central device), max.
- 6
- Fm
- Limited by number of slots and number of connections
- Cp, point-to-point
- CP 440: Limited by number of slots; CP 441: limited by number of connections
- Cp, lan
- Limited by number of slots and number of connections
- Profibus and ethernet cps
- 14; incl. CP 443-5 Ext. and IM 467
- Required slots
- 1
- Hardware clock (real-time clock)
- Yes
- Battery-backed and synchronizable
- Yes
- Resolution
- 1 ms
- Deviation per day (buffered), max.
- 1.7 s; Power off
- Deviation per day (unbuffered) max.
- 8.6 s; Power on
- Number/number range
- 0 to 7
- Range of values
- 0 to 32767 hours
- Granularity
- 1 hour
- Retentive
- Yes
- Supported
- Yes; Via CP and loadable FB
- To mpi, master
- Yes
- To mpi, slave
- Yes
- To dp, master
- Yes
- To dp, slave
- Yes
- In as, master
- Yes
- In as, slave
- Yes
- Interface type
- Integrated
- Physics
- RS 485 / PROFIBUS
- Isolated
- Yes
- Power supply to interface (15 to 30 v dc), max.
- 150 mA
- Number of connection resources
- 16
- Transmission rate, max.
- 12 Mbit/s
- Pg/op communication
- Yes
- Routing
- Yes
- Number of connections, max.
- 16
- Number of dp slaves, max.
- 64
- Equidistance mode support
- Yes
- Sync/freeze
- Yes
- Activation/deactivation of dp slaves
- Yes
- Direct data exchange (slave-to-slave communication)
- Yes
- Inputs, max.
- 244 byte
- Outputs, max.
- 244 byte
- Slots, max.
- 244
- Per slot, max.
- 128 byte
- Address area, max.
- 32
- User data per address area, max.
- 32 byte
- User data per address area, of which consistent, max.
- 32 byte
- Isochronous mode (application synchronized up to terminal)
- Yes
- User data per isochronous slave, max.
- 244 byte
- Equidistance
- Yes
- Shortest clock pulse
- 1 ms
- Max. cycle
- 32 ms
- Number of connectable ops without message processing
- 15
- Number of connectable ops with message processing
- 8
- Number of gd loops, max.
- 8
- Number of gd packets, transmitter, max.
- 8
- Number of gd packets, receiver, max.
- 16
- Size of gd packets, max.
- 64 byte
- Size of gd packet (of which consistent), max.
- 1 variable
- User data per job, max.
- 8 kbyte
- User data per job (of which consistent), max.
- 240 byte
- As server
- Yes
- As client
- Yes
- Overall
- 16
- Reserved for pg communication
- 1
- Reserved for op communication
- 1
- Number of login stations for message functions, max.
- 8
- Symbol-related messages
- Yes
- Block related messages
- Yes
- Simultaneously active alarm-s blocks, max.
- 70; ALARM_S/SQ blocks or ALARM_D/DQ blocks
- Alarm 8-blocks
- Yes
- Number of instances for alarm 8 and s7 communication blocks, max.
- 300
- Preset, max.
- 150
- Process control messages
- Yes
- Number of archives that can log on simultaneously (sfb 37 ar_send)
- 4
- Overall, max.
- 512
- In 100 ms grid, max.
- 0
- In 500 ms grid, max.
- 256
- In 1000 ms grid, max.
- 256
- Per message
- 1
- With 100 ms grid, max.
- 0
- With 500, 1000 ms grid, max.
- 1
- Status block
- Yes
- Single step
- Yes
- Number of breakpoints
- 4
- Status/control variable
- Yes
- Variables
- Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
- Number of variables, max.
- 64
- Forcing
- Yes
- Forcing, variables
- Inputs/outputs, bit memories, distributed I/Os
- Number of entries, max.
- 400
- Step 7
- Yes
- Command set
- see instruction list
- Nesting levels
- 8
- System functions (sfc)
- see instruction list
- System function blocks (sfb)
- see instruction list
- Lad
- Yes
- Fbd
- Yes
- Stl
- Yes
- Scl
- Yes
- Cfc
- Yes
- Graph
- Yes
- Higraph®
- Yes
- Dpsyc_fr
- 2
- D_act_dp
- 4
- Rd_rec
- 8
- Wr_rec
- 8
- Wr_parm
- 8
- Parm_mod
- 1
- Wr_dparm
- 2
- Dpnrm_dg
- 8
- Rdsysst
- 8; 1 to 8
- Dp_topol
- 1
- User program protection/password protection
- Yes
- Width
- 25 mm
- Height
- 290 mm
- Depth
- 219 mm
- Weight, approx.
- 720 g
- Last modified:
- 31.07.2014
- Subcategory
- Plc
- Subcategory 2
- S7-400
- Subcategory 3
- Siemens plc all
- Listing ID
- 88357427
Description
SIEMENS S7-400 6ES74122XG040AB0 SIMATIC S7-400, CPU 412-2,CENTRAL PROCESSING UNIT WITH:,256 KB WORKING MEMORY,,(128 KB CODE, 128 KB DATA),,1. INTERFACE MPI/DP 12 MBIT/S,,2. INTERFACE PROFIBUS DPSIMATIC S7-400, CPU 412-2,ZENTRALBAUGRUPPE MIT:,ARBEITSSPEICH