Specifications
- Condition
- new
- Dimensions
- 1.1cm*7.6cm*5.7cm
- Weight
- 0.1kg
- Mfr. part number
- 1734-IT2I
- Bently nevada
- Siemens; Triconex
- 330104-00-20-05-02-00
- 6ES7400-1TA01-0AA0; Triconex 9760-210
- 3300/03-01-00
- 6ES7350-2AH00-0AE0; Triconex 7400027-100
- 3500/60 133835-01
- C98043-A1682-L1; Triconex 7400165-510
- 3300/16-15-01-03-00-00-00
- C79-458-L7000-B315; Triconex 2755-020
- 330709-000-050-10-02-00
- 6DR2100-5; Triconex 3704E
- 128275-01
- 6AA6504-0AA; Triconex 4000029-010
- 3500/42 135489-02
- 6ES7492-1AL00-0AA0; Triconex 3481
- 3300/20
- 6DD1600-0AJ0; Triconex 8311
- 3500/42-06-ru
- 6ES7132-4BD02-0AA0; Triconex 2553 7400056-310
- 330130-040-01-05
- 6ES7315-1AF03-0AB0; Triconex 3351
- 3500/50 133450-01
- 6EP8106-0AC20; Triconex 4000093-320
- 3500/91-01-02-00
- 6ES7331-1KF02-0AB0; Triconex 4000103-520
- 88149-01
- 6GK1543-1AA01; Triconex 3636R
- 125768-01
- 39VIMCBN; Triconex 3510
- 125800-02
- 6ES7431-7KF10-0AB0; Triconex 7400028-100
- 330930-040-02-00
- 6ES7321-1BL00-0AA0; Triconex 4000042-125
- 3300/46-46-04-02-01
- A5E00103265; Triconex 3805EN
- 18745-04
- 39PSR4ANDN 16114-200/01; Triconex 4000043-332
- 126648-02
- 6ES7222-1HF22-0XA8; Triconex 4000042-320
- 3500/60 133827-01
- 6ES5948-3UA11; Triconex 2661
- Category
- Input/Output Modules in China
- Subcategory
- Plc
- Subcategory 2
- Control system components
- Listing ID
- 101729630
Description
HART Master Multi-drop Network Interface Module
The 1734-IT2I is a POINT I/O Analog Temperature Input Module. It has 2 Thermocouple Inputs and a Resolution of 15 bits with an Input Voltage of 75 mV.
The 1734-IT2I is a POINT isolated analog temperature input module. Two differential individually-isolated thermocouple inputs are available with this module. Eight bytes of scanner data (scanner Rx) and fault status data can be produced without consuming I/O data (scanner Tx).
The 1734-IT2I is a POINT isolated analog temperature input module. Two differential individually-isolated thermocouple inputs are available with this module. Eight bytes of scanner data (scanner Rx) and fault status data can be produced without consuming I/O data (scanner Tx). Status indicators let the users monitor the network status, module status, the status of input 0, and the status of input 1 in real time. The 1734-IT2I comes with a resolution of 15 bits at 2.5 µV/cnt.