GR-C010 3 point bend/flexure
- Manufacturer: cometech testing machines
Capacity: 10kN | Jaw face width: 40mm | Span: 22~260mm | Mini. load cell: 200N | Temperature limits: 0~200℃ | Up weight: 801g | Down weight: 5342g
Taichung City, TaiwanGR-B02A Wheel peel grips
- Manufacturer: cometech testing machines
Capacity: 200N | Wheel width: 12.7mm | Specimen thickness: 0.1~2mm | Temperature limits: -10~100℃ | Weight: 440g | Standard: ASTM D3330
Taichung City, TaiwanGR-A030 Eccentric Grips
- Manufacturer: cometech testing machines
Capacity: 2kN | Jaw face width: 52mm | Specimen thickness: 0.2~4mm | Mini. load cell: 200N | Temperature limits: -10~200℃ | Weight: 1143g
Taichung City, TaiwanGR-A020 Spring Loaded Fold Grips
- Manufacturer: cometech testing machines
Capacity: 2kN | Jaw face width: 44mm | Specimen thickness: 0.2~3mm | Mini. load cell: 200N | Temperature limits: -10~200℃ | Weight: 687g
Taichung City, TaiwanGR-B040 90° peel grips
- Manufacturer: cometech testing machines
Capacity: 200N | Jaw face width: 32mm | Specimen thickness: 0.01~2mm | Temperature limits: -10~100℃ | Weight: 1992g | Standard: ASTM D3330
Taichung City, TaiwanGR-E010 Yarn Grip
- Manufacturer: cometech testing machines
Capacity: 200N | Core diameter size: Ø0.1〜Ø1mm | Mini. load cell: 20N | Temperature limits: -10~200℃ | Weight: 432g | Standard: ASTM D2256
Taichung City, TaiwanGR-C040 3 point bend/flexure
- Manufacturer: cometech testing machines
Capacity: 10kN | Jaw face width: 200mm | Specimen thickness: 25~280mm | Mini. load cell: 1kN | Temperature limits: 0~200℃ | Up weight: 2774g | Down weight: 16622g
Taichung City, TaiwanManual Drop Dart Impact Tester Confirm to ASTM D1709 GB-9639 Standard
- Manufacturer: cometech testing machines
This tester conforms to test standard applicable for method A and method B. Clamp the plastic film on a round specimen holder (dia. 127mm). The impact head used in method A is dia. 38.1mm and in method B is dia. ...
Taichung City, TaiwanFull-Auto Rockwell Hardness Tester Confirm to GB/T230.2, JJS Z2245, EN-ISO6508, ASTME-18 Standard
Applications: Hard alloy / Surface hardened steel / Copper alloy / Carburized steel / Hard cast steel / Malleable casting / Annealed steel / Hardened steel /Aluminum alloy / Soft steel / Bearing steel Features: ●...
Taichung City, TaiwanAdhesion/Release Tester Confirm to FINAT 4 Standard
- Manufacturer: cometech testing machines
QC-527 test range can do low and high speed peel test and also for 90 ° 、180° multi-angle peel test. Low speed peeling force generally uses 300mm/min to proceed with test, testlow-stick adhesive label tear force....
Taichung City, TaiwanHardness Specimen Cutting Device
- Manufacturer: cometech testing machines
QC-603I is suitable for hardness flat shape of polymer material, as a fixed sample or specimen trimming purposes. It needs to base on forming of appearance to make mold and take slightly larger than finished prod...
Taichung City, TaiwanElectronic Drop Dart Impact Tester Confirm to ASTM D1709 GB-9639 Standard
- Manufacturer: cometech testing machines
This tester is according to test standard of method A and method B. The test plastic film is clipped on dia. 127mm of round clamp by very quick pneumatic way. The impact head method A is dia. 38.1mm and method B ...
Taichung City, TaiwanVicat Heat Deflection Tester Confirm to ASTM D648 ISO 75-1 Standard
- Manufacturer: cometech testing machines
The specimen is given a fixed 10N force (or 50N) at the center with a standard Ø1 mm pin, and the temperature should increase by 50 (or 120) degrees Celsius per hour. When the penetration depth of specimen reache...
Taichung City, TaiwanManual Molding Machine
- Manufacturer: cometech testing machines
QC-601B has parallel pressure plates and according to area of the material and force demand to choose machine type. Commonly used in powder compact, parts assembly, lamination work. Put the ingredients in the mid...
Taichung City, TaiwanCircular Sample Cutter Confirm to ISO3801, ASTM D3776, GB/T4669, BS2471 Standard
- Manufacturer: cometech testing machines
QC-PS can cut specimens of area 100cm², weighing specimen unit weight, the balance of the required minimum reading value should reach 0.01 g. The cutter can cut specimens that thickness are 5 mm. Cutting material...
Taichung City, Taiwan