EXCHANGERS 114711
Unused 979 sq. ft. horizontal heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 2.32 Design duty (MMBTU/Hr). Shell Design Rating : 150 psig @ 190 deg. F. Tube Design Rating: 120/FV psig @ 150/300 deg. F. ...
Cleveland, TXEXCHANGERS 113841
Used approximately 3480 sq. ft. 304 Stainless Steel shell & tube vertical heat exchanger. Mfg. by Harliss Specialties Corp in 1987. Shell SA515 Gr 70, 3' 1.25" diameter X 15' long. Maximum working pressure 75 ...
Cleveland, TXEXCHANGERS 114258
Used 62 sq. ft. horizontal 316 stainless steel shell & tube heat exchanger. Mfg. by Perry Products in 1987. Model #FTSSMX-62, 8.625" diameter x 8'0" long F/F, (40)-3/4" od x 18 gauge tubes. Shell rated 90 psi @ 3...
Cleveland, TXEXCHANGERS 113104
"As Is, Where Is" Unused Karbate Poly Bloc Heat Exchanger. Teflon Impregnated. Mfg. by Mersen in 2018. Model #PB24-20-TH-1-2. (1) Pass Axial, (2) Pass Radial, (20) Blocks. Graphite Block data. Total process side ...
Cleveland, TXEXCHANGERS 114249
Previously Utilized in an API Facility. Used Condenser for K-2407 / R-2408; 92 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel tubes MOC. 90 psi.
Cleveland, TXEXCHANGERS 92404
- Manufacturer: HEBELER CORP, FOR APV CREPACO
PLATE AND FRAME HEAT EXCHANGER; MFG. BY HEBELER CORP, FOR APV CREPACO IN 1996; MAX WORKING PRESSURE 225 PSI @ 200 DEG. F.; MINIMUM -20 DEG. F. @ 225 PSI; PLATE PACK, 166, 40" H X 19" W; OVERALL DIMENSIONS 5' HIGH...
Cleveland, TXEXCHANGERS 114720
Unused 872 sq. ft. vertical heat exchanger. Mfg. by Wuxi Chemical Equipment (China) in 2023. 11.473 Design duty (MMBTU/Hr). Shell Design Rating: 232/FV psig @ 430/300 deg. F. Tube Design Rating: 180/FV psig @ 38...
Cleveland, TXEXCHANGERS 102481
- Manufacturer: VRV SPA
MFG. BY VRV.SPA IN 2000; 8200MM LENGTH; 1100MM WIDTH; 1000MM HEIGHT; 97 SQM 316L (2RE69) TUBES CS (ASTM A51GR60) SHELL VERTICAL HEAT EXCHANGER/EVAPORATOR; TUBE PRESSURE 14 BAR @ 150/170 DEG. C.; SHELL 25 BAR ...
Cleveland, TXEXCHANGERS 113764
Used 424 sq. ft. Horizontal Exchanger. Mfg. by Perry Products in 1999. 14" diameter. Shell: Carbon Steel, 100 psi @ 350 deg. F. Tubes: 304L Stainless Steel, 100 psi @ 350 deg. F. With expansion joint.
Cleveland, TXEXCHANGERS 112798
Used 12,580 sq. ft. plate exchanger. Mfg. by Alfa Laval, Inc. in 2012. Model #TL35-BFD. Previous Service: Venturi scrubber pump around cooler. (2)14" inlets & (2) 14" outlets. (811) plates x .02" thick.
Cleveland, TXEXCHANGERS 114590
Unused 377.9 sq. ft. plate exchanger. Mfg. by Alfa Laval in 2023. MAWP: 150/FV psig @ 356 deg. F. MDMT: 150/FV psig @ -20 deg. F. Model T21-MFG. A-Dim 183 mm with (40) 0.6 mm plates.
Cleveland, TXEXCHANGERS 95061
- Manufacturer: SWECOMEX
KELLOGG #108-C UNUSED BFW EXCHANGER; BUILT FOR 1500 TPD KELLOGG AMMONIA PLANT; MFG. BY SWECOMEX IN 1988; 999MM X 6035 MM; 335M2; SHELL: 10.5 KG/CM @ 280 DEG. C.; TUBES 10.5 KG/CM @ 93 DEG. C.;
Cleveland, TXEXCHANGERS 114746
Unused 327 sq. ft. heat exchanger. Mfg. by Fabsco shell and Tube in 2023. 1.1 Design duty (MMBTU/Hr). Shell Design Rating: 400/FV psi @ 300 deg. F. Tube Design Rating: 310 psi @ 150 deg. F. Shell mawp 415/FV psi...
Cleveland, TXEXCHANGERS 114741
Unused 284 sq. ft. Horizontal heat exchanger. Mfg by Fabsco Shell and Tube in 2023.. 2.32 Design duty (MMBTU/Hr). Shell Design Rating: 95/FV psi @ 300 deg. F. Tube Design Rating: 120 psi @ 150 deg. F. Shell mawp ...
Cleveland, TXEXCHANGERS 114749
Unused 112 sq. ft. heat exchanger. Mfg. by Fabsco Shell and Tube in 2023. 0.203 Design duty (MMBTU/Hr). Shell Design Rating: 425/FV psi @ 300 deg. F. Tube Design Rating: 330 psi @ 150 deg. F. Shell mawp 430/FV p...
Cleveland, TX