EXCHANGERS 114558
Used 250 sq. ft. horizontal exchanger. 24" diameter x 6'0" F/F. Shell, tubes and heads stainless steel.
Cleveland, TXEXCHANGERS 113187
Used 380 sq. ft. Stainless Steel Heat Exchanger. Mfg. by Julius Montz Gmbh (Germany) in 2015. Elbow Bottom Head. (4) Lug supports. Shell rated MAWP FV/75 psi @ 392 deg. F. MDMT -20 deg. F. @ FV/75 psi. Tubes rate...
Cleveland, TXEXCHANGERS 113188
Used 223 sq. ft. Stainless Steel Heat Exchanger. Mfg. by Julius Montz Gmbh (Germany) in 2015. With Expansion Joint. Elbow Bottom Head. (4) Lug supports. Shell rates MAWP FV/75 psi @ 482 deg. F. MDMT -20 deg. F. @...
Cleveland, TXEXCHANGERS 114248
Previously Utilized in an API Facility. Used Condenser for K-2407 / R-2408; 340 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel tubes MOC. 90 psi.
Cleveland, TXEXCHANGERS 114247
Previously Utilized in an API Facility. Used Condenser for K-2405 / R-2406; 92 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel tubes MOC. 90 psi.
Cleveland, TXEXCHANGERS 112345
Used 110 sq. ft. horizontal exchanger. Mfg. by Energy Exchanger Company in 2012. 26" diameter x 10'0" F/F. Carbon Steel. Shell 242 psi @ 145 deg. F. Tubes 650 psi @ 265 deg. F. (534) 3/4" x .083". Previous Servic...
Cleveland, TXEXCHANGERS 114245
Used Condenser for K-2405 / R-2406; 92 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel shell, tubes and heads. 90 psi @ 390 deg. F rated shell and tubes.
Cleveland, TXEXCHANGERS 113125
Used 235 sq. ft. Exchanger. Mfg. by JD Cousins in 2003. Previous Service: 18" Evaporator.
Cleveland, TXEXCHANGERS 99557
KELLOGG #136-C; PREVIOUS SERVICE - SYN GAS METHANATOR FEED EXCHANGER; SHELL & BUNDLE REPLACED BY TEXAS METAL FAB IN 1981;
Cleveland, TXEXCHANGERS 114554
Used 325 sq. ft. vertical exchanger. 18" diameter x 10'0" F/F. Tubes and heads stainless steel.
Cleveland, TXEXCHANGERS 114549
Used 225 sq. ft. vertical exchanger. Mfg. by Perry Products in 2015. 12" diameter x 11'0" F/F. Shell, tubes and heads all 304L stainless steel. 100 psi @ 320 deg. F. shell. 75FV psi @ 320 deg. F. tubes. (104) 3/4...
Cleveland, TXEXCHANGERS 113761
Used 1448 sq. ft. double diameter horizontal exchanger. Mfg. by Perry Products in 1999. 26"/36" diameter x 18'0" F/F. Shell: 304LSS 100 psi @ 350 deg. F. Tubes: 304LSS 100 psi @ 350 deg. F. (444)-3/4" O.D. x 18 BWG.
Cleveland, TXEXCHANGERS 113776
Used 375 sq. ft. Exchanger. Mfg. by Gaspar in 2005. 14" diameter x 20'0" F/F. Shell: Carbon Steel, FV/123 psi @ 350 deg. F. Tubes: Hastelloy C 276, FV/123 psi @ 350 deg. F. (96) 3/4" O.D. x .065".
Cleveland, TXEXCHANGERS 114553
Used 420 sq. ft. vertical exchanger. 18" diameter x 12'0" F/F. Shell, Tubes and heads stainless steel.
Cleveland, TXEXCHANGERS 114556
Used 250 sq. ft. horizontal exchanger. 24" diameter x 6'0" F/F. Shell, tubes and heads stainless steel.