EXCHANGERS 114734
Unused 915 sq. ft. horizontal heat exchanger. 3.542 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. . Shell Design Rating: 135/FV psig @ 320 deg. F. Tube Design Rating: 175/FV psig @ 300...
Cleveland, TXEXCHANGERS 114707
Unused 103 sq. ft. horizontal heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 1.3 Design duty (MMBTU/Hr). Shell Design Rating : 220/FV psig @ 430/300 deg. F. Tube Design Rating: 232/FV psig @ 430/400 d...
Cleveland, TXEXCHANGERS 114708
Unused 103 sq. ft. horizontal heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 1.3 Design duty (MMBTU/Hr). Shell Design Rating : 220/FV psig @ 430/300 deg. F. Tube Design Rating: 232/FV psig @ 430/400 d...
Cleveland, TXEXCHANGERS 112335
Used 437 Sq. Ft. Horizontal Utube Heat Exchanger. Mfg. by Fabsco Shell and Tube LLC in 2012. All 304L Stainless Steel. 18"/24" diameter x 16'0" F/F. Previous Service: AGR Rich Flash Gas Cooler.
Cleveland, TXEXCHANGERS 112292
Used 437 Sq. Ft. Horizontal Utube Heat Exchanger. Mfg. by Fabsco Shell and Tube LLC in 2012. All 304L Stainless Steel. 18"/24" diameter x 16'0" F/F. Previous Service: AGR Rich Flash Gas Cooler.
Cleveland, TXEXCHANGERS 114775
Unused 2685 sq. ft. vertical heat exchanger. 7.5 Design duty (MMBTU/Hr). Mfg. by Alliance Fab (Graham) in 2022. Shell: 150 psi @ 212 deg. F. Tubes: 50FV psi @ 400 deg. F. 34" x 156". Primary Surface Condenser. ...
Cleveland, TXEXCHANGERS 114776
Unused 96 sq. ft. vertical heat exchanger. 0.4 Design duty (MMBTU/Hr). Mfg. by Alliance Fab (Graham) in 2022. Shell: 150 psi @ 212 deg. F. Tubes: 50FV psi @ 400 deg. F. 10" x 72". Secondary Surface Condenser. U...
Cleveland, TXEXCHANGERS 113157
Used approximately 150 sq. ft. Southern heat exchanger. Approximately 12" diameter X 6' long shell. 3/4" stainless steel tubes. Shell side 50 FV @ 250 degrees F. Tube side 50 psi @ 250 degrees F. Horizontal...
Cleveland, TXEXCHANGERS 113055
Used 904 sq. ft. Heat Exchanger. Mfg. by Ward Tank & Heat Exchanger in 2005. With expansion joint. Previous Service: Inlet Scrubber Cooler.
Cleveland, TXEXCHANGERS 114763
Unused 1,021 sq. ft. vertical Plate and Frame heat exchanger. 8.7 Design duty (MMBTU/Hr). Mfg. by APV (SPX Flow) in 2023. Shell: 150 psi @ 320 deg. F. Tubes: 150 psi @ 320 deg. F.; Model #L039M-10. Treated Feed...
Cleveland, TXEXCHANGERS 114773
Unused 1021 sq. ft. vertical Plate and Frame heat exchanger. 8.7 Design duty (MMBTU/Hr). Mfg. by APV (SPX Flow) in 2023. Model #L039M-10. Shell: 150 psi @ 320 deg. F. Tubes: 150 psi @ 320 deg. F.; Treated Feed R...
Cleveland, TXEXCHANGERS 113484
Used estimated 745 sq. ft. Horizontal 316L Stainless Steel Heat Exchanger. Mfg. by Sisterville Tank Works in 2007. (190) 3/4" O.D. x 065" Tubes. 20" diameter x 20'0" F/F. Shell Rated 150 psi @ 20 to 320 deg. F. ...
Cleveland, TXEXCHANGERS 114258
Used 62 sq. ft. horizontal 316 stainless steel shell & tube heat exchanger. Mfg. by Perry Products in 1987. Model #FTSSMX-62, 8.625" diameter x 8'0" long F/F, (40)-3/4" od x 18 gauge tubes. Shell rated 90 psi @ 3...
Cleveland, TXEXCHANGERS 113104
"As Is, Where Is" Unused Karbate Poly Bloc Heat Exchanger. Teflon Impregnated. Mfg. by Mersen in 2018. Model #PB24-20-TH-1-2. (1) Pass Axial, (2) Pass Radial, (20) Blocks. Graphite Block data. Total process side ...
Cleveland, TXEXCHANGERS 92404
- Manufacturer: HEBELER CORP, FOR APV CREPACO
PLATE AND FRAME HEAT EXCHANGER; MFG. BY HEBELER CORP, FOR APV CREPACO IN 1996; MAX WORKING PRESSURE 225 PSI @ 200 DEG. F.; MINIMUM -20 DEG. F. @ 225 PSI; PLATE PACK, 166, 40" H X 19" W; OVERALL DIMENSIONS 5' HIGH...
Cleveland, TX