EXCHANGERS 114707
Unused 100 sq. ft. horizontal heat exchanger. 1.3 Design duty (MMBTU/Hr). Shell: 220 FV @ 430/300 deg. F. Tubes: 232FV @ 430/400 deg. F. 12.25" X 84". T-20001 Recirculating exchanger. Nitrogen Purged.
Cleveland, TXEXCHANGERS 114708
Unused 100 sq. ft. horizontal heat exchanger. 1.3 Design duty (MMBTU/Hr). Shell: 220 FV @ 430/300 deg. F. Tubes: 232FV @ 430/400 deg. F. 12.25" X 84". T-20002 Recirculating exchanger. Nitrogen Purged.
Cleveland, TXEXCHANGERS 114717
Unused 333 sq. ft. horizontal heat exchanger. 7.9 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. Shell: 370 psi @ 300 deg. F. Tubes: 285 psi @ 330 deg. F. 15.5" X 16'7.5". Feed/Effluent...
Cleveland, TXEXCHANGERS 114715
Unused 333 sq. ft. horizontal heat exchanger. 7.9 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. Shell: 370 psi @ 300 deg. F. Tubes: 285 psi @ 330 deg. F. 15.5" X 16'7.5". Feed/Effluent...
Cleveland, TXEXCHANGERS 114719
Unused 360.24 sq. ft. horizontal heat exchanger. 2.05 Design duty (MMBTU/Hr). Shell: 170 psi @ 150 deg. F. Tubes: 215 psi @ 330 deg. F. 15.25" X 168". Stripped water cooler. Nitrogen Purged.
Cleveland, TXEXCHANGERS 113966
150 square meter 316L stainless steel tube, head and carbon steel shell vertical heat exchanger, design pressure tubeside 20 bar + full vacuum @ 100 degrees C, shell side 10 barg + full vacuum @ 100 degrees C, du...
Cleveland, TXEXCHANGERS 114704
Unused 220 sq. ft. horizontal heat exchanger. 3.6 Design duty (MMBTU/Hr). Shell: 180 FV @ 430/300 deg. F. Tubes: 232FV @ 430/400 deg. F. 15.5" X 108". T-100001 Recirculating exchanger. Nitrogen Purged.
Cleveland, TXEXCHANGERS 114709
Unused 100 sq. ft. horizontal heat exchanger. 1.3 Design duty (MMBTU/Hr). Shell: 220 FV @ 430/300 deg. F. Tubes: 232FV @ 430/400 deg. F. 12.25" X 84". T-10003 Recirculating exchanger. Nitrogen Purged.
Cleveland, TXEXCHANGERS 114712
Unused 22 sq. ft. horizontal heat exchanger. .25 Design duty (MMBTU/Hr). Shell: 180FV psi @ 430/300 deg. F. Tubes: 232FV @ 430/400 deg. F. 7.891" X 72". T-2002 Recirculating Exchanger. Nitrogen Purged.
Cleveland, TXEXCHANGERS 114718
Unused 333 sq. ft. horizontal heat exchanger. 7.9 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. Shell: 370 psi @ 300 deg. F. Tubes: 285 psi @ 330 deg. F. 15.5" X 16'7.5". Feed/Effluent...
Cleveland, TXEXCHANGERS 114716
Unused 333 sq. ft. horizontal heat exchanger. 7.9 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. Shell: 370 psi @ 300 deg. F. Tubes: 285 psi @ 330 deg. F. 15.5" X 16'7.5". Feed/Effluent...
Cleveland, TXEXCHANGERS 114711
Unused 979 sq. ft. horizontal heat exchanger. 2.32 Design duty (MMBTU/Hr). Shell: 150 psi @ 190 deg. F. Tubes: 120FV @ 150/300 deg. F. 25" X 168". Caustic Dilution Cooler. . Nitrogen Purged.
Cleveland, TXEXCHANGERS 114714
Unused 1055.7 sq. ft. heat exchanger. 6.214 Design duty (MMBTU/Hr). Shell: 232 psi @ 480 deg. F. Tubes: 200 psi @ 380 deg. F. 23.5" X 16'11". Acid gas stripper reboiler. Nitrogen Purged.
Cleveland, TXEXCHANGERS 114713
Unused 569.7 sq. ft. horizontal heat exchanger. 1.625 Design duty (MMBTU/Hr). Shell: 200FV psi @ 300 deg. F. Tubes: 155 psi @ 300 deg. F. 15.25" X 210". HGU condensate trim cooler (for HGU feed). . Nitrogen Purged.
Cleveland, TXEXCHANGERS 114720
Unused 953.17 sq. ft. vertical heat exchanger. Mfg. by Wuxi Chemical Equipment (China) in 2023. 11.473 Design duty (MMBTU/Hr). Shell: 232FV psi @ 430/300 deg. F. Tubes: 180FV psi @ 380/300 deg. F. 21.25" X 144"....
Cleveland, TX