EXCHANGERS 112941
used
Used 18,294 Sq. Ft. vertical Plate Exchanger. Mfg. by APV in 2012. With (2)20" inlets & (2)20" outlets. Model #S280M14 Paraflow. Previous Service: GI Closed Loop CW heat Exchanger 1;
Cleveland, TXEXCHANGERS 113760
used
Used 1957 sq. ft. vertical plate exchanger. Mfg. by Alfa Laval in 2016. Carbon Steel Frame and Alloy Plates. Model #T20-MFG.
Cleveland, TXEXCHANGERS 108629
used
LIQUEFACTION COOLER; 6.7 SQ. FT. PLATE HEAT EXCHANGER; MFG. BY ALFA LAVAL IN 2011; MODEL #TL3-PFG; NBRP GASKETS; PLATE THICKNESS .50MM;
Cleveland, TXEXCHANGERS 108627
used
PREP TANK HEATER; 3.4 SQ. FT. PLATE HEAT EXCHANGER; MFG. BY ALFA LAVAL IN 2011; MODEL #M3-FG; HNBR GASKETS; PLATE THICKNESS .60MM;
Cleveland, TXEXCHANGERS 108631
used
CIP DILUTE CAUSTIC HEATER; 9 SQ. FT. PLATE HEAT EXCHANGER; MFG. BY ALFA LAVAL IN 2011; MODEL #T5-MFG; EPDMP GASKETS; PLATE THICKNESS .50MM;
Cleveland, TXEXCHANGERS 113092
used
"As Is, Where Is" Used Karbate Poly Bloc Heat Exchanger Phenolic Impregnated. Model #PBC24-20PU-1-2. Built in 2016.
Cleveland, TXEXCHANGERS 114587
used
Unused 1999.1 sq. ft. plate exchanger. Mfg. by Alfa Laval in 2023. MAWP: 150/FV psig @ 200 deg. F. MDMT: 150/FV psig @ -20 deg. F. Model T21-MFG. A-Dim 949 mm with (205) 0.6 mm plates.
Cleveland, TXEXCHANGERS 114588
used
Unused 636.5 sq. ft. plate exchanger. Mfg. by Alfa Laval in 2023. MAWP: 150/FV psig @ 356 deg. F. MDMT: 150/FV psig @ -20 deg. F. Model T21-MFG. A-Dim 302 mm with (66) 0.6 mm plates.
Cleveland, TXEXCHANGERS 113316
used
Used Approximately 400 Sq. Ft. Plate Heat Exchanger. Mfg. by APV in 2009. Model N34 M-11. .5mm Thick Plates.
Cleveland, TXEXCHANGERS 108628
used
PREP TANK COOLER; 11.1 SQ. FT. PLATE HEAT EXCHANGER; MFG. BY ALFA LAVAL IN 2011; MODEL #TL3-PFG; NBRP GASKETS; PLATE THICKNESS .50MM;
Cleveland, TXEXCHANGERS 67353
used
- Manufacturer: APV BAKER
0.8 SQ METER 316SS PLATE HEAT EXCHANGER; MFG. BY APV BAKER IN 1996; TYPE 3HH-208/171; UNIT W/CYLINDRICAL SHELL, (23) 316SS PLATES (CYLINDRICAL, VERT) INSIDE SHELL...
Cleveland, TXEXCHANGERS 114154
used
696 sq. ft. Plate Heat Exchanger, Mfg. by Kelvion in 2022. With 316L Stainless Steel Plates. Rated 145 psig @ 230 deg. F. Model #NF150LBA150, plate type NF150L. 85 plates. 1mm plate thickness. NBR gasket material.
Cleveland, TXEXCHANGERS 114068
used
Used 73 sq. ft. (21) Plate Heat Exchanger. PMT-13 Cooler. Mfg. by APV in 2006. Size 13.875 x 36. 0.020". Shell: 316 Stainless Steel, 150 psi @ 300/-20 deg. F.
Cleveland, TXEXCHANGERS 102477
used
- Manufacturer: VICARB
ALFA LAVAL PLATE HEAT EXCHANGER MFG. BY VICARB IN 1993; APPROXIMATELY 150 SQ. FT.; PROCESS SIDE RATED 72.6 L; 3 BAR @ 75 DEGREES C.; SERVICE SIDE RATED 72.6L; 3 BAR @ 95 DEGREES C.; 1700MM LENGTH; 550MM WIDTH; 11...
Cleveland, TXEXCHANGERS 114150
used
596 sq. ft. Plate Heat Exchanger, Mfg. by Kelvion in 2022. With 316L Stainless Steel Plates. Rated 145 psig @ 230 deg. F. Model #NF150LBA150, Plate type NF150L, 73 plates. 1mm plate thickness. NBR gasket material.
Cleveland, TX