TL-47 Vitrek, measuring cables up to 4700
High-voltage measurement cables 10 kV , for the 4700 meter. Replacement set of test leads with direct input. This test leads include a low-voltage cable with a safety rating of 20 kV, a common input cable (both 1...
Łódź, Poland
1990688, MDL fuse 315mA/1000V, delayed
Delayed fuse, ceramic 0.315 A/1000V This 1000V fuse is filled with sand to absorb the shock energy generated by the current overload. It will also help absorb the high temperatures generated (up to 10,000 °F). Th...
Łódź, Poland
2002234, Mini fuse 50mA/250V – fast
Quick fuse used in FLUKE calibrators type 724, 725 do not use delayed action fuses in these meters , fuses look almost identical There are no reviews yet. Only logged in customers who have purchased this product ...
Łódź, Poland
2030852, MDL fuse 3.15A/500V, slow-blow
Delay fuse, ceramic 3,15A/500V, used in 165x and 166x meters rated voltage: 500V size: CH6.3 dimensions: 6.3×32 mm rated current: 3.15A
Łódź, Poland
3321245, MDL fuse 16A/500V time delay 6.3x32mm
Ceramic fuse used in Fluke Biomedical ESA 609, ESA 612, ESA 612, ESA 614 meters rated current: 16A permissible voltage:500V size: 6mm x 32mm
Łódź, Poland
Measuring attenuator 50 Ω, 1W
Coaxial terminator through 1 GHz, 50 Ω, 1W BNC. Necessary for connecting signals from sources 50 Ω to instruments with 1 MΩ impedance inputs, such as oscilloscopes. When calibrating an oscilloscope, necessary whe...
Łódź, Poland
LCD display up to 26-79
NOTE Display applicable to meters manufactured by FLUKE. Before ordering, check the service manual as to the proper selection of parts. In some meters due to design changes, di...
Łódź, Poland
FP700, 2A/1500V super fast fuse
Ceramic fuse commonly used in Fluke / BEHA / Amprobe / Martindale HD110C, HD160C meters rated current: 2A admissible voltage:1500V size: 6mm x 67mm
Łódź, Poland
832261, FLUKE, fuse, 125mA, Φ5 mm – free
- Manufacturer: Fluke
Fuse used in FLUKE calibrators There are no reviews yet. Only logged in customers who have purchased this product may leave a review.
Łódź, Poland
Keysight 2110-1547, MDL fuse, 3.15A 400VDC shorted
- Manufacturer: Agilent - Keysight
Ceramic delay fuse 3,15A/500V, used in Agilent, keysight meters 34460A 34461A 34465A 34470A rated voltage: 500V size: CH6.3 dimensions: 6.3×32 mm rated current: 3.15A
Łódź, Poland
FLU11A Fluke, fuse (pack of 5)
- Manufacturer: Fluke
Collective pack of 5 fuses Used in meters: 23-3, 26-3, 27, 45, 73-3, 75-3, 77-3, 77-4, 79-3, 89-4,111, 112, 115,117,175, 177, 179,187, 189, 287,289, 863, 865, 867,867B, 8845A, 8846A
Łódź, Poland
LCD display # 4413845 for 724, 725
NOTE Display applicable to meters manufactured by FLUKE. Before ordering, check the service manual as to the proper selection of parts. In some meters due to design changes, displays may have two or more versions...
Łódź, Poland
Measuring probe for model 1587
Remote trigger probe Dedicated measurement cable for Fluke 1587 , Fluke 1577 , Fluke 1507 , Fluke 1503 Remote probe with built-in test button to facilitate one-handed measurements
Łódź, Poland
Crocodile 1000V / 20A, Pamona, set red and black
Measuring crocodile fully insulated, allowable voltage of 1000V and current up to 20 A nickel-plated contact elements, the jaws of the crocodile open to 25 mm. 20A/1000V Alligator Clip is fully insulated. The cli...
Łódź, Poland
AC72, crocodile handle set red and black
The product is withdrawn from production, with us still available. The crocodile is designed for TL71, TL75 type leads.Set of 2 crocodiles ( red and black). Modular clips are used with modular test leads and prov...
Łódź, Poland